6.6 ALARM RECORD SETTING MENU
ALARM SETTING MENU
CH OP TYPE DURATION
1 | ON | N.O | 05 SECS |
2 | ON | N.O | 05 SECS |
3 | ON | N.O | 05 SECS |
4 | ON | N.O | 05 SECS |
(5 | ON | N.O | 05 SECS) |
(6. | ON | N.O | 05 SECS) |
RST ON | N.O |
|
Columns in brackets () only valid for
In ALARM RECORDING MENU, we define
(1)CH (Alarm input) : Select alarm input or RST for alarm reset input.
(2)OP (OPERATION) : ON : Records when alarm occurs.
OFF : No reaction when alarm occurs.
(3)TYPE : Select alarm type:
N.C. : Normally Closed with time out function counting from alarm start (set in DURATION)
N.C. + TRANS : Normal Closed, alarm duration as long as contacts is active + timeout (set in DURATION)
N.O. : Normal Open with time out function counting from alarm start (set in DURATION)
N.O. + TRANS: Normal Open, alarm duration as long as contact is active + timeout (set in DURATION)
(4)DURATION : Timeout duration time for each event. 0~99 seconds adjustable.
Turn the JOG dial clockwise or
Press ENTER key to confirm the option and move to next column.
ENTER
Press CALL key to confirm the option and move to previous column.
CALL
Press MENU key to return to Main Menu, press again to leave Set up Menu.
MENU