EverFocus EDSR-400, EDSR-600 instruction manual Record Setting Menu

Page 24

MENU

6.8 RECORD SETTING MENU

RECORD SETTING MENU

NORMAL RECORD

SPEED

: 50 IPS

QUALITY

: STANDARD

DISK FULL

: REWRITE

ALARM RECORD

ON

OPERATION

SPEED

: 50 IPS

QUALITY

: STANDARD

PRE-ALARM RECORD

OPERATION

ON

In NORMAL RECORDING MENU, we define

(1)NORMAL RECORD:

SPEED : To set the normal recording speed. Maximum 60 (NTSC) / 50 (PAL).

QUALITY: Video recording quality setup for setting the quality of the vi deo picture by selecting a compression rate. There are six quality levels for recording

LOWER

: 15 KB

LOW

: 19 KB

BASIC

: 23 KB

STANDARD : 27 KB

HIGH

: 31 KB

SUPERIOR

: 35 KB

DISK FULL: Set REWRITE or STOP when HDD is full.

(2)ALARM RECORD (for Alarm In and Motion detection):

OP (Operation): Select ON or OFF to activate alarm recording or not.

SPEED : To set the alarm and motion recording speed. Maximum 60 (NTSC) / 50 (PAL).

QUALITY: Video recording quality setup, this item lets you set the quality of the video picture by selecting a compression rate.

NOTE: The recording rates are for the total system: The single camera record rate is: Camera record rate = System record rate / Number of connected cameras Example: Record Rate 60 IPS, 6 connected cameras: 10 IPS / camera

(3)PRE-ALARM RECORD: (with Alarm In and Motion)

Pre – Alarm duration is depending on record quality (about 8-15 seconds). OP (Operation): Select ON or OFF to activate pre-alarm recording or not .

Turn the JOG dial clockwise or counter-clockwise to select the options.

Press ENTER key to confirm the option and move to next column.

ENTER

Press CALL key to confirm the option and move to previous column.

CALL

Press MENU key to return to Main Menu, press again to leave Set up Menu.

MENU

19

Image 24
Contents EDSR-600 V1.05 2004/3/25Safety Precautions Power Disconnect Important Safeguards Important SafeguardsTable of Contents Product Overview Product OverviewSpecifications SpecificationsBack Panel Connections Back Panel ConnectionsON/OFF VideoAlarm I/O Refer pin assignment in Appendix-D, Before Installation System ConnectionSystem Connection Front Panel Keypads Front Panel KeypadsShuttle Ring and JOG Dial Chanel KeysIR Remote Controller receiver Press Menu key to enter SET UP Menu OperationOperation Insert a HDD IDE for Video StorageMenu flow Menu FlowCall Clock Setting Menu CLOCK/LANGUAGE Setting Menu , we defineTimer Setting Menu Wrong DLY Start 2000 Stop Correct DLY Start 2000 StopSequence Setting Menu Sequence Setting MENU, we define for Main MonitorTitle Setting Menu Title Setting Menu , we defineCovert Setting Menu Covert Setting Menu , we defineDefault setting is OFF for all cameras Alarm Record Setting Menu Alarm Recording MENU, we defineMotion Setting Menu Motion Record Setting MENU, we defineOP Operation Default OFF Press 1-4/6 to Manual Edit Record Setting Menu Network Setting Menu Network Setting MENU, we defineUSER-NAME Password Level MAC AddressControl Setting Menu Control Setting MENU, we defineBuzzer Setting Menu Archive Setting Menu Picture SizeTime Stamp Water MarkCall Monitor Setting Menu CH, DWELL, EventDisk Setting Menu Disk Setting MENU, we defineDisk Usage HDD-1, HDD-2 System Setting Menu System Setting MENU, we definePlay with Audio AUDIO-1, AUDIO-2 Alarm Recording RecordingInstant Recording RECPlaying Back Normal PlaybackPlay PauseSearch Playback Search PlaybackSearch EnterAlarm List search playback Date/Time Search Playback Search StopData Export Still Image CopyPause Copy Copy to Movie File MenuAlarm Export Event LOG ListPress „DISPLAY key and hold key for about 2 seconds DisplayMode Display Zoom Monitor Views / OperationCall monitor Main MonitorSetting Call Monitor Call MonitorsRemote Control 11.1 RS-485 Remote ControlRJ45 RS485 pin assignment IR Remote Controller IR Remote Controller optionalEDSR600 Channel keys #1~6 #1~16 valid for EDSR900/1600 only View From Internet/Intranet Main Screen View From Internet/Intranet View From Internet/Intranet Specifications Appendix-A? When Recording with 160GB HDD Appendix-BEstimated with typical image-low noise level ? When Recording with 320GB HDD 59259.3Appendix C Serial Interface Specifications DVRHost Remote Control Protocol Sample control code packetsFormat of message packet is as follows Length ByteReceiver ID Opcode Byte & Data bytes OPcodeRemote keys OPcode=0x4B Checksum ByteAlarm I/O pin assignment Appendix-DPIN # ALM1~ALM4 EDSR400, ALM1~ALM6 EDSR600Head Office European Office Beijing OfficeUSA Office Japan Office