EverFocus EDSR-400, EDSR-600 11.1 RS-485 Remote Control, RJ45 RS485 pin assignment

Page 42

11. REMOTE CONTROL

11.1 RS-485 REMOTE CONTROL

The new standard EverFocus EDSR remote protocol allows challenging installations with DVR remote control at different installation sites.

EDSR remote control is supported by the optional keyboards KS-KBJ(with 3-axis joystick and 2 additional RS-485 – Ports for telemetry control with independent telemetry protocols) and KS-KBK(no telemetry).

Up to 32 units are allowed in the RS -485 bus. The RS -485 bus requires serial wiring with 2-wire shielded twisted pair cable(“daisy chain”). Maximum cable length of the bus is 1200 m.

Star wiring is only possible with additional RS -485 distributor. Mixed installation is possible with following recorder types:

EDSR100H, EDSR100M, EDSR400H, EDSR400M, EDSR400, EDSR600, EDSR900, EDSR1600 For installation details please consult the manuals of KS-KBK and KS-KBJ keyboard.

Installation example (2 remote operators, 1 EDSR600, 1 EDSR1600) :

MAIN1 M1-1 M1-2

M1-3 M1-4

Video 1 x

 

 

 

 

Video 5 x

 

 

Video 5 x

 

 

Video 1 x

CALL 1 CALL 2

MAIN2

 

RS-485 2 wire

 

RS-485 2 wire

Operator 1:

Operator 2:

1x Full screen view DVR1

1x Multi screen view DVR1 (MAIN)

1x Full screen view DVR2

4x Full screen view DVR1 (MATRIX)

 

1x Multi screen view DVR1 (MAIN)

DVR1: EDSR1600

RS-485 2 wire

DVR2: EDSR600

RJ45 (RS485) pin assignment

There are two RJ-45 (RS-485) connectors on the back panel of the DVR (loop through). Please refer the following pin assignment for application.

 

 

 

 

 

 

 

 

 

 

 

 

 

PIN

FUNCTION

 

1

2

3 4

5

6

 

7

8

 

 

 

 

 

 

 

 

1

GND

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

3

RX +

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

RX -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

8

NC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

37

Image 42
Contents EDSR-600 V1.05 2004/3/25Safety Precautions Power Disconnect Important Safeguards Important SafeguardsTable of Contents Product Overview Product OverviewSpecifications SpecificationsON/OFF Back Panel ConnectionsBack Panel Connections VideoAlarm I/O Refer pin assignment in Appendix-D, Before Installation System ConnectionSystem Connection Shuttle Ring and JOG Dial Front Panel KeypadsFront Panel Keypads Chanel KeysIR Remote Controller receiver Operation Press Menu key to enter SET UP MenuOperation Insert a HDD IDE for Video StorageMenu flow Menu FlowCall Clock Setting Menu CLOCK/LANGUAGE Setting Menu , we defineTimer Setting Menu Wrong DLY Start 2000 Stop Correct DLY Start 2000 StopSequence Setting Menu Sequence Setting MENU, we define for Main MonitorTitle Setting Menu Title Setting Menu , we defineCovert Setting Menu Covert Setting Menu , we defineDefault setting is OFF for all cameras Alarm Record Setting Menu Alarm Recording MENU, we defineMotion Setting Menu Motion Record Setting MENU, we defineOP Operation Default OFF Press 1-4/6 to Manual Edit Record Setting Menu USER-NAME Password Level Network Setting MenuNetwork Setting MENU, we define MAC AddressControl Setting Menu Control Setting MENU, we defineBuzzer Setting Menu Time Stamp Archive Setting MenuPicture Size Water MarkCall Monitor Setting Menu CH, DWELL, EventDisk Setting Menu Disk Setting MENU, we defineDisk Usage HDD-1, HDD-2 System Setting Menu System Setting MENU, we definePlay with Audio AUDIO-1, AUDIO-2 Instant Recording Alarm RecordingRecording RECPlay Playing BackNormal Playback PauseSearch Search PlaybackSearch Playback EnterAlarm List search playback Date/Time Search Playback Search StopData Export Still Image CopyPause Copy Copy to Movie File MenuPress „DISPLAY key and hold key for about 2 seconds AlarmExport Event LOG List DisplayCall monitor Mode Display ZoomMonitor Views / Operation Main MonitorSetting Call Monitor Call MonitorsRemote Control 11.1 RS-485 Remote ControlRJ45 RS485 pin assignment IR Remote Controller IR Remote Controller optionalEDSR600 Channel keys #1~6 #1~16 valid for EDSR900/1600 only View From Internet/Intranet Main Screen View From Internet/Intranet View From Internet/Intranet Specifications Appendix-A? When Recording with 160GB HDD Appendix-BEstimated with typical image-low noise level ? When Recording with 320GB HDD 59259.3Appendix C Serial Interface Specifications DVRHost Remote Control Protocol Sample control code packetsFormat of message packet is as follows Length ByteReceiver ID Remote keys OPcode=0x4B Opcode Byte & Data bytesOPcode Checksum BytePIN # Alarm I/O pin assignmentAppendix-D ALM1~ALM4 EDSR400, ALM1~ALM6 EDSR600USA Office Head Office European OfficeBeijing Office Japan Office