AXIS 2460 User’s Manual | Setting up Events and Alarms | 27 |
Send an email to [email address] when this event occurs
Send email - Check this box to send an
Include Image - Checking this box will attach to the
Note: If you see the text (No Mail Recipient is Specified), an address must be entered on the
Complete Alarm Settings
This section describes how to configure alarms for the four inputs and one output. Note that this describes the configuration of the physical alarm devices connected to the Network DVR. These settings will also influence the behaviour of the alarm LEDs on the front panel.
Input Settings
The following settings can be configured for each input:
Enabled - Check to enable the input. This must always be done if you want the various events to be able to use the input.
Input Name - Used wherever the input is shown. Use a descriptive name.
Generated When Circuit is... - Select Open (Falling) or Closed (Rising). The correct setting will depend on the actual device used, and whether it generates an alarm when the circuit closes or when it opens. This setting does not determine if the alarm input is enabled or not, but simply how it functions. Nor does the setting have anything to do with the settings for Active/Inactive on the event settings page.
Output Relay Settings
When the output relay is enabled on this page it will then be available to all events, which in turn can have the relay enabled or disabled, independently of each other. The settings available are Enabled and Output Name, as described above for inputs.
After making these settings, click Save.