CHAP. 5 Set Up
4) INTERVAL SETUP
Set the switching time interval for SEQ or PIP function.(1 sec. ~ 99 sec.)
INTERVAL SETUP |
|
|
|
SWICHING INTERVAL |
|
FULL SCREEN | 01 SEC |
PIP SCREEN | 01 SEC |
|
|
(1)FULL SCREEN : set the sequencing switch time interval EVENT RECORD
in live full screen. | EVENT UPDATE TIME | 01 SEC |
|
|
(2)PIP SCREEN : set the sequencing switch time interval of PIP window.
SELECT ▲▼◀▶, CHANGE VALUE : - +
(3)EVENT UPDATE TIME : Set the minimum time interval of event to be listed in EVENT LIST.
If EVENT UPDATE TIME is set at 20 sec, only following event happened
20 sec or more than 20 sec later previous event shall be listed in EVENT LIST.
5) ALARM SETUP
Set type of alarm sensors connected to DVR unit. N.O represents Normal Open type and N.C Normal Close type.
(1)ALARM INPUT : Select type of alarm sensor connected to DVR unit (N.O or N.C). Use direction button and
DISABLE represents not to use alarm sensor connected to DVR.
(2)DURATION : Set the duration of alarm when an alarm is activated. (0 sec. ~ 300 sec.)
6)EVENT POPUP SETUP
When event is activated, the full image will pop up as user set.
(1)CHANNEL : Choose a channel
(2)POPUP ON/OFF : Set a popup function at ON/OFF
(3)EVENT : Set event mode which ‘popup’ function is applied to.
*A : ALARM event. M : MOTION event.
(4)DURATION : Set the duration how long the popup Image is shown.(0 sec. ~ 60 sec.)
※If more than 2 channels pop up at the same time, the first channel out of them will be shown.
(For e.g. Ch1 and CH3 pop up at the same time, CH1 will be shown)
| ALARM SETUP | ||
|
|
|
|
CHANNEL |
|
| CH1 |
ALARM INPUT |
|
| N.O |
DURATION |
|
| 005 |
|
|
|
|
N.O | NORMAL OPEN | ||
N.C | NORMAL CLOSE | ||
___ | DISABLE | ||
|
|
|
|
SELECT : ▲▼, CHANGE VALUE : - +
EVENT POPUP SETUP |
|
|
|
CHANNEL | CH01 |
POPUP ON / OFF | ON |
EVENT | AM |
DURATION | 0 3 |
|
|
|
|
SELECT : ▲▼, CHANGE VALUE : - +
25