CHAP. 5 Set Up
(5) EVENT SERVER SETUP : |
|
| |
IP ADDRESS : IP Address of PC that executes |
|
| |
EVENT SERVER SETUP | |||
EVENT SERVER PROGRAM. | |||
IP PORT : PORT of PC that executes | IP ADDRESS | 192.168.001.072 | |
EVENT SERVER PROGRAM | |||
IP PORT | 09988 | ||
EVENT SERVER TYPE : | |||
EVENT SERVER TYPE | OFF | ||
| |||
It is the way to transmit data to SERVER | INTERVAL | ||
| |||
By "OFF", "EVENT", "MINUTE“, | EVENT GMT TYPE | GMT+00:00 | |
In case Event happens from DVR. |
|
|
"EVENT“: It transmits by the number of EVENT.
"MINUTE“: It transmits each scheduled time.
INTERVAL: If EVENT SERVER TYPE is "EVENT"
User can select from 1~512.
If EVENT SERVER TYPE is "MINUTE“, User can select from 1 ~ 60 mins.
EVENT GMT TYPE : User can set currently installed location(DVR) of GMT.
2)
User can control the DVR via
This function is mainly for programmer who wants to control DVR as part of many devices connected to PC system, as in SI project.
|
| |
|
|
|
SPEED |
| 115200 |
LENGTH |
| 8 |
STOP BIT |
| 1 |
PARITY |
| NONE |
|
|
|
SELECT : ▲▼, CHANGE VALUE : + -
3) PANTILT SETUP
It is to set parameters for PTZ camera connected to DVR unit. DVR unit already includes all protocols of
PANTILT SETUP |
|
| COMMAND SETTING | |||||
|
|
|
|
|
|
|
|
|
|
|
| CHANNEL |
| 01 |
|
|
|
|
|
| MODEL |
|
| |||
|
|
| PTZ ID |
| 000 |
|
|
|
COMMAND SETTING | PTZ camera set |
| BAUDRATE |
| 2400 BPS |
| ||
|
|
| CMD DELAY |
| 1 MSEC |
|
| |
SPEED SETTING | PTZ speed set |
|
|
|
|
|
|
|
|
|
| COMMAND |
| PAN/TILT STOP | |||
|
|
| LENGTH |
| 07 |
|
|
|
|
|
| CODE |
| FF | 00 | 00 | 00 |
|
|
|
|
| 00 | 00 | 00 | 00 |
|
|
|
| |||||
SELECT : ▲▼, & [ENTER] |
| SELECT : ▲▼, CHANGE VALUE : + - | ||||||
| ||||||||
|
|
|
|
|
|
|
|
|
(1)CHANNEL : Select channel
(2)MODEL : Select camera model (protocol type) per each channel
(3)PTZ ID : Select ID
(4)BAUDRATE : Select data transmission speed
(5)CMD DELAY : Select command delay time
32