Philips TH-37PR10U Serial Terminals connection, Communication parameters, Command

Page 11

Connections

SERIAL Terminals connection

The SERIAL terminal is used when the Plasma Display is controlled by a computer.

COMPUTER

1

2

3

4

5

 

 

 

6

7

8

9

RS-232C Straight cable

SERIAL

 

 

 

 

Pin layout for SERIAL Terminal

D-sub 9p

Notes:

Use the RS-232C cable to connect the computer to the Plasma Display.

The computer shown is for example purposes only.

Additional equipment and cables shown are not supplied with this set.

The SERIAL terminal conforms to the RS-232C interface specification, so that the Plasma Display can be controlled by a computer which is connected to this terminal.

The computer will require software which allows the sending and receiving of control data which satisfies the conditions given below. Use a computer application such as programming language software. Refer to the documentation for the computer application for details.

Communication parameters

Signal level

RS-232C compliant

Synchronization method

Asynchronous

Baud rate

9600 bps

Parity

None

Character length

8 bits

Stop bit

1 bit

Flow control

-

RS-232C Conversion cable

D-sub 9-pin female

Details

 

2

R X D

 

3

T X D

4

5

GND

6

Non use

 

7

Shorted

 

8

 

 

1

9

NC

Basic format for control data

The transmission of control data from the computer starts with a STX signal, followed by the command, the parameters, and lastly an ETX signal in that order. If there are no parameters, then the parameter signal does not need to be sent.

STX C1 C2 C3 : P1 P2 P3 P4 P5 ETX

 

Colon

Parameter(s)

End

Start

3-character

(1 - 5 bytes)

(03h)

(02h)

command (3 bytes)

 

 

Notes:

If multiple commands are transmitted, be sure to wait for the response for the first command to come from this unit before sending the next command.

If an incorrect command is sent by mistake, this unit will send an “ER401” command back to the computer.

SL1A, SL1B, SL2A and SL2B of Command IMS are available only when a dual input terminal board is attached.

Command

Command

Parameter

Control details

PON

None

Power ON

POF

None

Power OFF

AVL

**

Volume 00 - 63

AMT

0

Audio MUTE OFF

1

Audio MUTE ON

 

IMS

None

Input select (toggle)

 

SL1

Slot1 input

 

SL2

Slot2 input

 

SL3

Slot3 input

 

PC1

PC input

 

SL1A

Slot1 input (INPUT1A)

 

SL1B

Slot1 input (INPUT1B)

 

SL2A

Slot2 input (INPUT2A)

 

SL2B

Slot2 input (INPUT2B)

DAM

None

Screen mode select (toggle)

 

NORM

NORMAL (4 : 3)

 

ZOOM

ZOOM

 

FULL

FULL

 

JUST

JUST

 

SELF

Panasonic AUTO

With the power off, this display responds to PON command only.

11

Image 11
Contents Model No. Número de modelo Operating Instructions Manual de instruccionesEnglish Español Risk of Electric Shock Do not Open Important Safety Instructions Table of Contents Trademark Credits FCC CautionCanadian Notice When using the Plasma Display Safety PrecautionsIf problems occur during use MaintenanceSetup AC Power Supply CordCheck that you have the Accessories and items shown AccessoriesAccessories Supplied AC cord fixing ConnectionsPC Input Terminals connection Signal Names for Mini D-sub 15P ConnectorBasic format for control data CommandSerial Terminals connection Communication parametersConnecting the plug to the Wall Outlet Power on / OFFConnecting the AC cord plug to the Plasma Display INPUT1 INPUT2 INPUT3 PC Selecting the input signalInitial selections Selecting the On-Screen Menu LanguageOn OFF Basic ControlsDigital Zoom see Press to access Channel AdjustmentVolume Adjustment OFF Timer buttonSound POS. /SIZE Advanced SettingsOn-Screen Menu Displays On Time / Power OFF Time / Power OFF TimePicture Explanation During Multi PIP OperationsNormal Full RGB/PC in mode Adjusting POS. /SIZEClock Phase Clock PhaseMulti PIP 1366x768@60Hz RGB, DVI, Hdmi Advanced PIPOne screen Advanced PIP Press to exit from Options menu Sub screen Main screenCinema Picture AdjustmentsStandard DynamicAdvanced Settings Mute Sound AdjustmentSelect the magnification required for the enlarged display Digital ZoomDisplay the operation guide PositionButton Forward Present Time SetupPresent Time Setup Press to set up DAY or Present Time of DAYPower on Time / Power OFF Time SET UP TimerDisplay the SET UP Timer Screen Press to select Negative / Scroll selection Mode selectionStart setting Screensaver For preventing image retentionReduces screen image retention Setup of Screensaver TimePress to exit from Screensaver Side BAR AdjustOFF Dark MID Bright Addition sign Selected Input Reduces power consumptionCustomizing the Input labels Component RGB SET UP for Input SignalsComponent / RGB in Select 3D Y/C Filter For Ntsc AV imagesColor System Color System / Panasonic AutoPulldown / Video NR FREQ. kHz / V-FREQ. Hz Setting RGB sync signalSync Refresh RateOptions Adjustments Off MENU&ENTER On Off Initial VOL Sets normal volume LevelVolume display can go up to 63 regardless of the settings Becomes the same as the Maximum VOL levelNormal Standby EnableInitial Power FunctionRotate Off Does not rotate the image State regardless of the slot power setting InstallationNormalization Weekly Command Timer Press to set each item Press to select a command numberPress to select Time / Command Time Set the time to execute a command programShipping condition Plasma Display panel TroubleshootingSymptoms Checks Symptoms CheckRGB PC input signalsCommand list of Weekly Command Timer Specifications Limits and Exclusions Panasonic Canada Inc Limited Warranty StatementPanasonic Canada Inc Customer’s RecordPanasonic Professional Display Company Executive Office