Philips TH-42PH10EK operating instructions Adjusting Pos. / Size, Normalisation

Page 19

Adjusting Pos. / Size

1

2

3

Press to display the Pos. /Size menu.

Press to select H-Pos / H-Size / V-Pos / V-Size /

Clock Phase.

Press to adjust Pos. / Size.

During “AV(S Video)”, “Component” and “Digital” input signal.

4 Press to exit from adjust mode.

Notes:

Adjustment details are memorized separately for different input signal formats (Adjustments for component signals are memorized for 525 (480) / 60i · 60p, 625 (575) / 50i · 50p, 1125 (1080) / 60i · 50i · 24p · 25p · 30p · 24sF, 1250 (1080) / 50i, 750 (720) / 60p · 50p each, and RGB/PC/Digital signals are memorized for each frequency.)

If a “Cue” or “Rew” signal from a VCR or DVD player is received, the picture position will shift up or down. This picture position movement cannot be controlled by the Picture Pos./Size function.

If adjusting the Picture V-Pos/V-Size in Panasonic Auto with 16:9 mode, the adjustment is not memorized. When exiting the mode, the screen will return to a former adjustment.

Pos. /Size

 

Normalise

Normal

 

 

 

 

 

 

 

 

 

 

H-Pos

0

 

 

 

 

 

 

 

H-Size

0

 

 

 

 

 

 

 

 

 

 

 

 

V-Pos

0

 

 

 

 

 

 

 

 

 

 

V-Size

0

 

 

 

 

 

 

 

 

 

During “RGB / PC” input signal.

Pos. /Size

Normalise Normal

 

 

 

H-Pos

0

 

 

 

 

 

 

 

H-Size

0

 

 

 

 

 

 

 

V-Pos

0

 

 

 

 

 

 

 

 

 

 

V-Size

0

 

 

 

 

 

 

 

 

 

Clock Phase

0

 

 

 

 

 

 

H-PosAdjust the horizontal position.

H-SizeAdjust the horizontal size.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V-PosAdjust the vertical position.

V-SizeAdjust the vertical size.

 

 

 

 

 

 

 

 

 

 

 

 

Clock Phase

Eliminate the flickering and distortion.

(RGB/PC in mode)

 

Helpful Hint ( /

Normalise

Normalisation)

While the Pos. / Size display is active, if either the N button on the remote control is pressed at any time or the ACTION () button is pressed during “Normalise”, then all adjustment values are returned to the factory settings.

19

Image 19
Contents Model No. TH-42PH10EK High Definition Plasma DisplayOperating Instructions Model No. TH-42PS10EKTable of Contents Trademark Credits Important Safety NoticeTransport only in upright position Safety PrecautionsSetup Do not place any objects on top of the Plasma DisplayWhen using the Plasma Display Safety PrecautionsIf problems occur during use Electric shocks can result if this is not done Clean the power cable regularly to prevent it becoming dustyAccessories Supply AccessoriesRemote Control Batteries Speakers ConnectionsAC cord fixing PC Input Terminals connection Signal Names for Mini D-sub 15P ConnectorConnections Communication parameters CommandSerial Terminals connection ComputerVideo VCR Camcorder AV connection for TH-42PH10EK/S, TH-50PH10EK/S, TH-58PH10EKConnecting the AC cord plug to the Plasma Display Power On / OffConnecting the plug to the Wall Outlet INPUT1 INPUT2 INPUT3 PC Selecting the input signalInitial selections Selecting the On-Screen Menu LanguageBasic Controls Basic Controls On-Screen Menu Displays On-Screen Menu Displays Pressed Aspect mode changes each time the Enter button isAspect Controls Board TY-FB9BD, Panasonic Auto cannot be selectedNormalisation Adjusting Pos. / SizeMulti PIP TH-42PS10EK/STH-58PH10EK Advanced PIPCinema Picture AdjustmentsNormal DynamicPicture Adjustments Advanced settingsHigh Effect Details BlackLow G Mute Sound AdjustmentSelect the magnification required for the enlarged display Digital ZoomDisplay the operation guide Select the area of the image to be enlargedPresent Time Setup Present Time Setup / Set up TimerPresent Time Setup / Set up Timer Set up TimerReversal / Scroll selection Mode selectionStart setting Screensaver For preventing image retentionReduces screen image retention Setup of Screensaver TimeScreensaver For preventing image retention This function may be applicable to the non-picture area Side Panel AdjustmentComposite Reduces power consumptionCustomizing the Input labels Addition sign Selected InputHow to Setup Multi Display Setup for Multi Display× 2 F × 3 F × 4 F Press twice to exit from Setup Setup for Multi DisplayDisplay Number locations for each arrangement Press to select × 1, × 2, × 3, × Press to select Vertical ScaleDisplay Number locations for each arrangement. Examples Power On Screen DelayID Cancellation Seam hides video SettingID Remote Control Function ID remote control button operationRGB Setup for Input SignalsComponent / RGB-in select 3D Y/C Filter For Ntsc AV imagesColour system / Panasonic Auto Setup for Input SignalsCinema reality / P-NR Displays the H Horizontal / V Vertical frequencies Setting RGB sync signalSync Freq. kHz / V-Freq. HzEffect Adjustments Options AdjustmentsOptions Adjustments Remocon NormalizationLocks Buttons on bottom face of main unit Off User1 User2Timer CommandOff User1 User2 User3 Off MENU&ENTER OnOff Press Menu & Enter PressMode Off-timer EnableInitial Power Normal StandbySlot1 Indicates unset Press to select a dayPress to select a program number You can set the program from 1 toProgram Command setting screenShipping condition Plasma Display panel TroubleshootingPAL60 VIDEO/PC input signalsVideo input for TH-42PH10EK/S, TH-50PH10EK/S, TH-58PH10EK PALCommand list of Weekly Command Timer Specifications TH-42PH10EK/S TH-50PH10EK/S TH-58PH10EK SpecificationsCustomer’s Record For business users in the European Union