Philips TH-42PH10EK Off MENU&ENTER On, Off Press, Menu & Enter Press, Off User1 User2 User3

Page 45

Options Adjustments

Options

1/3

Weekly Command Timer

Onscreen display

 

On

 

 

 

 

 

Initial INPUT

 

Off

 

 

 

 

 

Initial VOL level

Off

0

 

 

 

 

 

Maximum VOL level

Off

0

 

 

 

 

 

INPUT lock

 

Off

 

 

 

 

 

Button lock

 

Off

 

 

 

 

 

Remocon User level

 

Off

 

 

 

 

 

Advanced PIP

 

Off

 

Item

Effect

Adjustments

Press button to adjust the volume when the unit is turned on.

 

 

Off

On

Initial VOL

 

Off:

Sets normal volume.

level

Off On

On:

Sets your preferred volume.

 

 

Notes:

 

When “Maximum VOL level” is “On”, the volume can only be adjusted between 0 and your maximum range.

You can hear the changed volume regardless of your volume setting before opening the options menu if you adjust the volume when “Initial VOL level” is “On” and cursor is on the menu.

Press button to adjust the maximum volume.

 

 

 

Off

On

 

 

 

 

 

 

Off:

Sets auto maximum volume.

 

Maximum VOL

 

 

On:

Sets your preferred maximum volume.

level

Off

On

Notes:

 

 

 

 

 

 

 

• If the “Maximum VOL level” is set lower than the “Initial VOL level”, the “Initial VOL level”

 

 

 

automatically becomes the same as the “Maximum VOL level”.

 

 

 

• The volume display can go up to 63 regardless of the settings.

 

 

 

• You can hear the changed volume regardless of your volume setting before opening the options menu if you

 

 

 

adjust the volume when “Maximum VOL level” is “On” and cursor is on the menu.

 

 

 

Off

PC

INPUT1

INPUT2

INPUT3

 

 

 

Locks the input switch operation.

 

 

 

 

Notes:

 

 

 

 

 

 

 

• Only the adjusted signal is displayed (see page 13).

INPUT lock

 

 

• Signal can be displayed when the Terminal board is installed.

 

 

• Input switch can be used when this is set to “Off”.

 

 

 

In two screen display mode, if anything other than “Off” is set, the value will be fixed as the value input in the single screen display mode.

When a dual input terminal board is attached, A or B is displayed depending on the selected input signal. (Ex. INPUT1A, INPUT1B)

Off MENU&ENTER On

Off: All the buttons at the bottom of the main unit can be used.

MENU & ENTER:

Locks and buttons on bottom face of main unit.

 

 

 

MENU

ENTER/

 

 

 

 

 

 

 

 

 

Button lock

On:

Locks all the button on bottom face of main unit.

 

 

 

 

 

 

Sets Button lock with the unit buttons in the following procedure.

 

 

 

 

Off: Press

four times→Press

 

four times→Press

four times→Press

 

 

MENU & ENTER: Press

 

INPUT

 

four times→Press

ENTER/

 

 

four times→Press

four times→Press

 

 

On: Press

 

ENTER/

 

 

four times→Press

 

 

INPUT

 

ENTER/

 

four times→Press

 

four times→Press

 

 

 

 

 

 

 

ENTER/

 

 

 

 

ENTER/

 

 

Off

User1

User2

 

 

User3

 

 

 

 

 

 

 

Off:

You can use all of the buttons on the remote control.

 

 

 

 

Remocon

User1:You can only use

,

,

,

,

,

,

,

buttons on the remote

control.

 

 

 

 

 

 

 

 

 

 

 

User level

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

User2:You can only use , buttons on the remote control.

User3:Locks all the buttons on remote control.

 

Off:

 

Sets normal two screen display mode (see page 20).

Advanced PIP Off On

On:

 

Sets Advanced PIP mode (see page 21).

Notes:

 

 

• When “INPUT lock” is “On”, you cannot use all the two screen display functions.

 

,

buttons are unavailable during Advanced PIP mode operation.

45

Image 45
Contents Operating Instructions High Definition Plasma DisplayModel No. TH-42PS10EK Model No. TH-42PH10EKTable of Contents Trademark Credits Important Safety NoticeSetup Safety PrecautionsDo not place any objects on top of the Plasma Display Transport only in upright positionSafety Precautions When using the Plasma DisplayIf problems occur during use Electric shocks can result if this is not done Clean the power cable regularly to prevent it becoming dustyAccessories Accessories SupplyRemote Control Batteries Connections SpeakersAC cord fixing Signal Names for Mini D-sub 15P Connector PC Input Terminals connectionConnections Serial Terminals connection CommandComputer Communication parametersVideo VCR Camcorder AV connection for TH-42PH10EK/S, TH-50PH10EK/S, TH-58PH10EKPower On / Off Connecting the AC cord plug to the Plasma DisplayConnecting the plug to the Wall Outlet Initial selections Selecting the input signalSelecting the On-Screen Menu Language INPUT1 INPUT2 INPUT3 PCBasic Controls Basic Controls On-Screen Menu Displays On-Screen Menu Displays Aspect Controls Aspect mode changes each time the Enter button isBoard TY-FB9BD, Panasonic Auto cannot be selected PressedNormalisation Adjusting Pos. / SizeMulti PIP TH-42PS10EK/STH-58PH10EK Advanced PIPNormal Picture AdjustmentsDynamic CinemaPicture Adjustments Advanced settingsEffect Details Black HighLow G Mute Sound AdjustmentDisplay the operation guide Digital ZoomSelect the area of the image to be enlarged Select the magnification required for the enlarged displayPresent Time Setup Present Time Setup / Set up TimerPresent Time Setup / Set up Timer Set up TimerStart setting Mode selectionScreensaver For preventing image retention Reversal / Scroll selectionSetup of Screensaver Time Reduces screen image retentionScreensaver For preventing image retention This function may be applicable to the non-picture area Side Panel AdjustmentCustomizing the Input labels Reduces power consumptionAddition sign Selected Input CompositeHow to Setup Multi Display Setup for Multi DisplaySetup for Multi Display × 2 F × 3 F × 4 F Press twice to exit from SetupDisplay Number locations for each arrangement Press to select × 1, × 2, × 3, × Press to select Vertical ScaleDisplay Number locations for each arrangement. Examples Power On Screen DelayID Remote Control Function Seam hides video SettingID remote control button operation ID CancellationComponent / RGB-in select Setup for Input Signals3D Y/C Filter For Ntsc AV images RGBSetup for Input Signals Colour system / Panasonic AutoCinema reality / P-NR Sync Setting RGB sync signalFreq. kHz / V-Freq. Hz Displays the H Horizontal / V Vertical frequenciesEffect Adjustments Options Adjustments Options Adjustments Locks Buttons on bottom face of main unit NormalizationOff User1 User2 RemoconTimer CommandOff Press Off MENU&ENTER OnMenu & Enter Press Off User1 User2 User3Initial Power Off-timer EnableNormal Standby ModeSlot1 Press to select a program number Press to select a dayYou can set the program from 1 to Indicates unsetProgram Command setting screenShipping condition Plasma Display panel TroubleshootingVideo input for TH-42PH10EK/S, TH-50PH10EK/S, TH-58PH10EK VIDEO/PC input signalsPAL PAL60Command list of Weekly Command Timer Specifications TH-42PH10EK/S TH-50PH10EK/S TH-58PH10EK SpecificationsCustomer’s Record For business users in the European Union