Graco 244561 important safety instructions Fluid Dispense

Page 31

Status line

 

 

 

FLUID DISPENSE

ID#

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fluid 1

Fluid 2

Fluid 3

 

 

 

 

 

 

 

 

 

 

 

 

Idle

Idle

Idle

Target

005.00 ltr

050.00 ltr

010.10 ltr

Actual

5.00 ltr

51.00 ltr

10.00 ltr

Tolerance %

5

5

5

 

 

Difference %

0

+2

-1

 

 

 

 

 

 

 

 

 

 

Run

Totals

Alarms

 

 

 

 

 

 

 

 

 

 

 

STOP

AUTO ON

Dispense

DISPENSE

 

 

Switch AUTO

DISPENSE

 

START

 

 

START

 

ti1359a

Dispense Mode

Fluid Dispense

Fluid Dispense displays in the Run screen if “Fluid Sta- tion” is selected as the Dispense Mode. Fluid Dispense allows you to select a fluid panel and the amount to dis- pense on an individual basis.

1.Place the fluid panel dispense line into the recepta- cle.

2.Type a 4 digit ID# if desired.

3.In the column for the fluid you want to dispense, type the desired amount of fluid in the Target field.

4.Press the Start button on the Remote Operator Sta- tion to begin dispensing the fluid.

5.As the fluid dispenses, the status on the screen changes from Idle to Dispense and the amount dis- pensed appears in the Actual row.

6.The fluid panel stops dispensing when its Target is reached.

309301G

31

Image 31
Contents ProDispense 309301G Part No Electronic Preset Dispense SystemContents Parts ProDispense Controller Part No ProDispense System ComponentsWater/Antifreeze Grease/Paint MeterlessDure ConventionsFIRE, EXPLOSION, and Electric Shock Hazard High Pressure Fluid HAZARD/SKIN Injection Hazard Fluid Supply OverviewHow the ProDispense System Works UsageProDispense Controller Main ComponentsDisplay and EasyKey Pad Number Keys Previous Field Display Operation Mode Switch B and Key C Power Switch aRemote Operator Stations 244599 244600 244601 Fluid PanelsKey 246837 246838 246839 Key for FIG InstallationProDispense System Typical Installation Install the Fluid SuppliesFluid Panel 244601 Mount the Fluid PanelsConnect the Air and Fluid Lines Fluid Panel 244599Fluid Panel Install the Remote Operator StationMount the Controller Connect the Cables and Power Cord Check the Resistance Ground the SystemConnect a Printer optional Connect to a PC or Alarm optionalBefore Beginning Operation ProDispense Rev StartupShutdown Pressure Relief ProcedureScreen Navigation Setup ModeTo enter Setup Mode To exit Setup ModeTo setup the system System Setup ScreenTo set up the fluids Fluid Setup ScreenFluid Panel Meter Type Factor Cc/pulse To calibrate a meter Recipe Setup Screen To setup the recipes Calibrate Meter ScreenRecipe Dispense Dispense ModeRun Screen Idle, Dispense, and Alarm StatusRecipe Dispense Fluid Dispense Fluid DispenseFluid Totals Fluid Totals ScreenInvalid K-factor Alarm Alarm History ScreenOut of Tolerance Alarm Dispense Timeout AlarmAutomatic Dispense Operation ProceduresLoading Fluid Lines Manual DispenseEmergency Stop Purging FluidProblem Cause Solution TroubleshootingRemoving and Installing Controller ServiceTo remove controller To install controller Replacing Display Board Replacing Membrane Replacing DisplayReplacing Main Board Replacing Power Supply Replacing Fluid Panel Junction Box Ti1404a Service Replacing Fluid Meter or Solenoid Servicing Fluid PanelTi1413a If replacing solenoid If replacing meterTi1412a Replacing Fluid Meter, Solenoid, or Dispense Valve Servicing Fluid Panel 244601If replacing dispense valve Show meter removal Replacing Solenoid or Dispense Valve Service 309301G Replacing Fluid Meter, Solenoid, or Dispense Valve Show meter removal Control Box Wiring Chart Wiring ChartsWire / Harness Connection Color Function Color Function Wire / HarnessHarness Connection Color Function Fluid Panel Wiring ChartFluid panels Field Wiring Chart Output Accessories Wiring ChartHarness Connection Color Function Connector-Pin Service 309301G Part No , Controller PartsDescription Qty Item 18 Cover Assembly Part No , Fluid Panel Ti1322a 10, 11, 12 19, 23, 24 Ti1324a Part No , Fluid Panel Qty Description309301G Power Requirements Technical DataMeter-less Flow meter supplied by user Wetted Parts Accessories and KitsGraco Information Graco Standard WarrantyToll Free, 612-623-6921, 612-378-3505 Fax