4.As appropriate, either continue copying to other pumps, or touch Return to go back to the “Pump Setup” screen.

Copying to a Range of Other Pumps:

1.On the “Pump Copy” screen (Figure 10) touch the gray First Pump button. The keypad pops up.

2.Enter the pump number for the lower end of the range you are copying to. Use

(Backspace Key) to erase any mistakes. Use (Enter Key) to enter the value. The keypad disappears, and the “Pump Copy” screen shows the pump number you entered under First Pump.

3.On the “Pump Copy” screen (Figure 10), touch the gray Last Pump button. The keypad pops up.

4.Enter the pump number for the upper end of the range you are copying to. Use

(Backspace Key) to erase any mistakes. Use (Enter Key) to enter the value. The keypad disappears, and the “Pump Copy” screen shows the pump number you entered under Pump Station.

5.Touch the green Copy to Range of Pumps button. Complete briefly appears on the screen.

6.As appropriate, either continue copying to other pumps, or touch Return to go back to the “Pump Setup” screen.

Copying to All Other Pumps:

1.On the “Pump Copy” screen (Figure 10), touch the green Copy to All Pumps button. Complete briefly appears on the screen.

2.Touch Return to go back to the “Pump Setup” screen.

Finishing Setup: Setting Up Passwords

You can set up passwords for two levels of security: for operators and for setup personnel. The controller comes from the factory with neither password set. This allows every user access to all functions.

Setup Password

If you define a password for setup personnel, then most settings can be changed only after entering the password. The password will be required to display the following screens:

System Setup (to review and change system-wide settings, clear the alarm log, and go to the network status screens).

Station Setup (to review and change settings for all station options).

Pump Setup (to review and change settings for all pump options).

3–Pump 33-Station Controllers

Chapter 3: Installation

25 of 51

Image 26
Contents SCC 3-Pump 33-Station Controllers Parts and Service Department Shipping Information Table of Contents Maintenance Configurable Settings Contract Department Safety Symbols Used in this Manual SafetyHow to Use This Manual Wear Safety Glasses and Work Gloves Responsibility General ResponsibilityOperator Responsibility Maintenance ResponsibilityReporting a Safety Defect General Description Functional DescriptionModels Covered in This Manual Mechanical Features Standard FeaturesOptional Features Electrical FeaturesSafety Device Lock-Outs Safety Devices and InterlocksSafety Circuit Standards Fail Safe OperationUncrating InstallationMaking Control Panel Power Drop Wiring Connections Mounting the Control PanelConnecting the Control Panel to Vacuum Hoppers Connecting the Control Panel to the Pump PackageSetup Setting the Number of Stations and the Number of PumpsSystem Setup Screen Before Setup Setting Up Alarm Silences System Setup ScreenSetting Up Pump Staging Setting Up Touch Switch DelaySetting Up Stations Setting Up a Single StationStation Setup Screen Copying Settings from One Station to Others Station Copy ScreenPage Setting Up Pumps Setting Up a Single PumpCopying Settings from One Pump to Others Pump Copy ScreenFinishing Setup Setting Up Passwords Setup PasswordOperator Password Initial Startup Basic Tasks OperationOverview Reviewing Station StatusColor Label Description Reviewing Pump Status Pump Status Screen During OperationPassword Entry Screen Logging On and Logging OffEnabling and Disabling Stations and Pumps Starting and Stopping the SystemReviewing and Adjusting Basic Station Settings Navigating among the Station Operator ScreensAdjusting Convey Time and Dump Delay Activating and Stopping Priority Convey for a Station Adjusting Advanced Settings Reviewing and Resetting a Pump Hour MeterTransferring Stations to a Standby Pump Transfer To Standby Pump ScreenTransfer To Standby Pump Button Reviewing Alarms AlarmsStandby Pump Errors Silencing Alarms Maintenance Configurable Settings Options for Station Setup# attempts before Options for Pump Setup Idle Time OptionsTroubleshooting General TroubleshootingSystem Alarms Station AlarmsPump Alarms Optional Components WarrantyAppendix Drawings and Diagrams Pump 33 station Controller with 6 DisplayAC Voltage Spare Parts ListReturned Material Policy DC VoltageController Safety Tags Safety Tag InformationWarranty Returns Controller Identification Serial Number TagParts Department Service DepartmentTechnical Assistance Contact Information Sales Department

882.00252.00, CV3-635 specifications

The Sterling Plumbing CV3-635,882.00252.00 is a revolutionary addition to home plumbing solutions, designed to enhance efficiency and convenience. This model stands out in the market due to its innovative features, advanced technologies, and sturdy characteristics, making it a reliable choice for homeowners and professionals alike.

One of the main features of the CV3-635 is its high water efficiency. Engineered to reduce water consumption without sacrificing performance, this plumbing fixture is ideal for environmentally conscious users. It is designed to meet or exceed regulatory standards for water flow, ensuring optimal operation while helping to conserve precious resources.

The CV3-635 also incorporates state-of-the-art technology, including SmartFlow technology, which allows for precise water temperature control. This feature ensures that users can enjoy consistent and comfortable water temperatures, eliminating the risk of sudden temperature fluctuations. With a user-friendly interface, adjustments can be made easily, accommodating the needs of every member of the household.

Durability is a key characteristic of the Sterling Plumbing CV3-635,882.00252.00. Constructed with high-quality materials, it resists leaks and corrosion, ensuring a long lifespan. The polished chrome finish not only enhances its aesthetic appeal but also provides added protection against wear and tear, making it a stylish yet practical addition to any bathroom or kitchen.

Installation of the CV3-635 is straightforward, thanks to its user-friendly design. This model is compatible with standard plumbing configurations, allowing for quick setup and minimal disruption. The comprehensive installation guide that accompanies the product ensures that even less experienced users can install it with confidence.

Another notable feature is its noise-reduction technology, which minimizes operational sounds, creating a quieter environment in the home. This is particularly beneficial in multi-story houses where plumbing sounds can disturb lower levels.

The Sterling Plumbing CV3-635,882.00252.00 is not just a plumbing fixture; it is a commitment to sustainability, performance, and style. With its innovative features, advanced technologies, and robust construction, it stands as a premium choice in modern plumbing solutions, appealing to both eco-conscious consumers and design-savvy homeowners.