Sterling Plumbing CV3-635 Reviewing Pump Status, Pump Status Screen During Operation

Page 31

Reviewing Pump Status

The “Pump Status” screen is the counterpart of the “Station Status” screen. To reach the “Pump Status” screen from any other screen, touch Menu on the right-hand side of the screen, and then touch Pumps. The “Pump Status” screen appears.

Figure 12: “Pump Status” Screen During Operation

The status of each pump is color-coded. You can see an explanation of each status by using the online help. To do so from this screen, complete the following steps:

1.Touch Menu. The “Menu” screen appears.

2.Touch Help. The “Help Menu” screen appears.

3.Touch Pump States. The “Pump Symbols Help” screen appears, explaining the status represented by each color.

4.When you are finished reviewing the information, touch Return. The “Help Menu” appears.

5.Touch Menu to return to the “Menu” screen.

The following table explains the status represented by each color at the Station Status screen.

Color

Label

Description

Gray outline

Offline

Pump is not enabled. The controller ignores any alarms.

Yellow

Ready

Pump is off, waiting for demand from a station.

Blue

Idle

Pump is on, waiting for demand from a station. If there is no

 

 

demand before the end of the auto shutdown delay, the pump

 

 

will turn off.

Green

Loading

Pump is conveying material to a station.

Blue, blinking

Blow Back

Pump’s air filter is being cleaned by blowing compressed air

 

 

backward through it.

Red, blinking

Alarm

Pump is in alarm.

Red outline, blinking

Critical

Pump is in critical alarm. The controller has disabled the pump

 

 

until the alarm is cleared.

Additional basic information about each pump, including configuration settings and the number of hours the pump has been running, is available at the “Pump Setup” screen. For details on configuration settings, see page 44. For details on the hour meter, see page 36.

3–Pump 33-Station Controllers

Chapter 4: Operation

30 of 51

Image 31
Contents SCC 3-Pump 33-Station Controllers Parts and Service Department Shipping Information Table of Contents Maintenance Configurable Settings Contract Department How to Use This Manual SafetySafety Symbols Used in this Manual Wear Safety Glasses and Work Gloves General Responsibility ResponsibilityReporting a Safety Defect Maintenance ResponsibilityOperator Responsibility Models Covered in This Manual Functional DescriptionGeneral Description Electrical Features Standard FeaturesOptional Features Mechanical FeaturesFail Safe Operation Safety Devices and InterlocksSafety Circuit Standards Safety Device Lock-OutsMounting the Control Panel InstallationMaking Control Panel Power Drop Wiring Connections UncratingConnecting the Control Panel to the Pump Package Connecting the Control Panel to Vacuum HoppersSetting the Number of Stations and the Number of Pumps SetupSystem Setup Screen Before Setup System Setup Screen Setting Up Alarm SilencesSetting Up Touch Switch Delay Setting Up Pump StagingSetting Up a Single Station Setting Up StationsStation Setup Screen Station Copy Screen Copying Settings from One Station to OthersPage Setting Up a Single Pump Setting Up PumpsPump Copy Screen Copying Settings from One Pump to OthersSetup Password Finishing Setup Setting Up PasswordsOperator Password Initial Startup Reviewing Station Status OperationOverview Basic TasksColor Label Description Pump Status Screen During Operation Reviewing Pump StatusLogging On and Logging Off Password Entry ScreenStarting and Stopping the System Enabling and Disabling Stations and PumpsNavigating among the Station Operator Screens Reviewing and Adjusting Basic Station SettingsAdjusting Convey Time and Dump Delay Activating and Stopping Priority Convey for a Station Reviewing and Resetting a Pump Hour Meter Adjusting Advanced SettingsTransfer To Standby Pump Screen Transferring Stations to a Standby PumpTransfer To Standby Pump Button Standby Pump Errors AlarmsReviewing Alarms Silencing Alarms Maintenance Options for Station Setup Configurable Settings# attempts before Idle Time Options Options for Pump SetupGeneral Troubleshooting TroubleshootingPump Alarms Station AlarmsSystem Alarms Appendix WarrantyOptional Components Pump 33 station Controller with 6 Display Drawings and DiagramsDC Voltage Spare Parts ListReturned Material Policy AC VoltageController Identification Serial Number Tag Safety Tag InformationWarranty Returns Controller Safety TagsSales Department Service DepartmentTechnical Assistance Contact Information Parts Department

882.00252.00, CV3-635 specifications

The Sterling Plumbing CV3-635,882.00252.00 is a revolutionary addition to home plumbing solutions, designed to enhance efficiency and convenience. This model stands out in the market due to its innovative features, advanced technologies, and sturdy characteristics, making it a reliable choice for homeowners and professionals alike.

One of the main features of the CV3-635 is its high water efficiency. Engineered to reduce water consumption without sacrificing performance, this plumbing fixture is ideal for environmentally conscious users. It is designed to meet or exceed regulatory standards for water flow, ensuring optimal operation while helping to conserve precious resources.

The CV3-635 also incorporates state-of-the-art technology, including SmartFlow technology, which allows for precise water temperature control. This feature ensures that users can enjoy consistent and comfortable water temperatures, eliminating the risk of sudden temperature fluctuations. With a user-friendly interface, adjustments can be made easily, accommodating the needs of every member of the household.

Durability is a key characteristic of the Sterling Plumbing CV3-635,882.00252.00. Constructed with high-quality materials, it resists leaks and corrosion, ensuring a long lifespan. The polished chrome finish not only enhances its aesthetic appeal but also provides added protection against wear and tear, making it a stylish yet practical addition to any bathroom or kitchen.

Installation of the CV3-635 is straightforward, thanks to its user-friendly design. This model is compatible with standard plumbing configurations, allowing for quick setup and minimal disruption. The comprehensive installation guide that accompanies the product ensures that even less experienced users can install it with confidence.

Another notable feature is its noise-reduction technology, which minimizes operational sounds, creating a quieter environment in the home. This is particularly beneficial in multi-story houses where plumbing sounds can disturb lower levels.

The Sterling Plumbing CV3-635,882.00252.00 is not just a plumbing fixture; it is a commitment to sustainability, performance, and style. With its innovative features, advanced technologies, and robust construction, it stands as a premium choice in modern plumbing solutions, appealing to both eco-conscious consumers and design-savvy homeowners.