Sterling Plumbing 882.00252.00, CV3-635 Reviewing and Adjusting Basic Station Settings

Page 34

Reviewing and Adjusting Basic Station Settings

The 3-pump, 33-station controller has a “Station Operator” screen for each station, as shown below. This screen enables you to review and adjust all basic settings for the station.

To reach the “Station Operator” screen, complete the following steps:

1.Go to the “Station Status” screen, if needed. To reach this screen from any other screen, touch Menu, and then touch Stations.

2.Touch and hold the icon for the station, until the controller either prompts for the password or displays the “Station Operator” screen. Once you have entered the password (if needed), the “Station Operator” screen appears.

Figure 14: “Station Operator” Screen

Settings in the box labeled Convey, the red Priority Convey Activate button, and the menu controls on the right-hand side of the screen appear for all stations. Buttons in light gray are settings that you can adjust at this screen. Boxes in dark gray are for display only. If a pump assignment needs to be changed, this must be done at the “Station Setup” screen.

Navigating among the Station Operator Screens

The controls in the upper right-hand corner of the screen enable you to move among the “Station Operator” screens:

To display the screen for the next lower-numbered station (for example, to move from the screen for Station 15 to the screen for Station 14), touch ◄ Back.

To display the screen for the next higher-numbered station (for example, to move from the screen for Station 15 to the screen for Station 16), touch Next ►.

To display the screen for a specific station, touch Goto. A keypad pops up. Enter the

number for the desired station. Use (Backspace Key) to erase any mistakes. Use (Enter Key) to enter the value.

To exit to the “Station Status” (or “Pump Status”) screen, touch Stations (or Pumps).

3–Pump 33-Station Controllers

Chapter 4: Operation

33 of 51

Image 34
Contents SCC 3-Pump 33-Station Controllers Parts and Service Department Shipping Information Table of Contents Maintenance Configurable Settings Contract Department How to Use This Manual SafetySafety Symbols Used in this Manual Wear Safety Glasses and Work Gloves Responsibility General ResponsibilityReporting a Safety Defect Maintenance ResponsibilityOperator Responsibility Models Covered in This Manual Functional DescriptionGeneral Description Mechanical Features Standard FeaturesOptional Features Electrical FeaturesSafety Device Lock-Outs Safety Devices and InterlocksSafety Circuit Standards Fail Safe OperationUncrating InstallationMaking Control Panel Power Drop Wiring Connections Mounting the Control PanelConnecting the Control Panel to Vacuum Hoppers Connecting the Control Panel to the Pump PackageSetup Setting the Number of Stations and the Number of PumpsSystem Setup Screen Before Setup Setting Up Alarm Silences System Setup ScreenSetting Up Pump Staging Setting Up Touch Switch DelaySetting Up Stations Setting Up a Single StationStation Setup Screen Copying Settings from One Station to Others Station Copy ScreenPage Setting Up Pumps Setting Up a Single PumpCopying Settings from One Pump to Others Pump Copy ScreenFinishing Setup Setting Up Passwords Setup PasswordOperator Password Initial Startup Basic Tasks OperationOverview Reviewing Station StatusColor Label Description Reviewing Pump Status Pump Status Screen During OperationPassword Entry Screen Logging On and Logging OffEnabling and Disabling Stations and Pumps Starting and Stopping the SystemReviewing and Adjusting Basic Station Settings Navigating among the Station Operator ScreensAdjusting Convey Time and Dump Delay Activating and Stopping Priority Convey for a Station Adjusting Advanced Settings Reviewing and Resetting a Pump Hour MeterTransferring Stations to a Standby Pump Transfer To Standby Pump ScreenTransfer To Standby Pump Button Standby Pump Errors AlarmsReviewing Alarms Silencing Alarms Maintenance Configurable Settings Options for Station Setup# attempts before Options for Pump Setup Idle Time OptionsTroubleshooting General TroubleshootingPump Alarms Station AlarmsSystem Alarms Appendix WarrantyOptional Components Drawings and Diagrams Pump 33 station Controller with 6 DisplayAC Voltage Spare Parts ListReturned Material Policy DC VoltageController Safety Tags Safety Tag InformationWarranty Returns Controller Identification Serial Number TagParts Department Service DepartmentTechnical Assistance Contact Information Sales Department

882.00252.00, CV3-635 specifications

The Sterling Plumbing CV3-635,882.00252.00 is a revolutionary addition to home plumbing solutions, designed to enhance efficiency and convenience. This model stands out in the market due to its innovative features, advanced technologies, and sturdy characteristics, making it a reliable choice for homeowners and professionals alike.

One of the main features of the CV3-635 is its high water efficiency. Engineered to reduce water consumption without sacrificing performance, this plumbing fixture is ideal for environmentally conscious users. It is designed to meet or exceed regulatory standards for water flow, ensuring optimal operation while helping to conserve precious resources.

The CV3-635 also incorporates state-of-the-art technology, including SmartFlow technology, which allows for precise water temperature control. This feature ensures that users can enjoy consistent and comfortable water temperatures, eliminating the risk of sudden temperature fluctuations. With a user-friendly interface, adjustments can be made easily, accommodating the needs of every member of the household.

Durability is a key characteristic of the Sterling Plumbing CV3-635,882.00252.00. Constructed with high-quality materials, it resists leaks and corrosion, ensuring a long lifespan. The polished chrome finish not only enhances its aesthetic appeal but also provides added protection against wear and tear, making it a stylish yet practical addition to any bathroom or kitchen.

Installation of the CV3-635 is straightforward, thanks to its user-friendly design. This model is compatible with standard plumbing configurations, allowing for quick setup and minimal disruption. The comprehensive installation guide that accompanies the product ensures that even less experienced users can install it with confidence.

Another notable feature is its noise-reduction technology, which minimizes operational sounds, creating a quieter environment in the home. This is particularly beneficial in multi-story houses where plumbing sounds can disturb lower levels.

The Sterling Plumbing CV3-635,882.00252.00 is not just a plumbing fixture; it is a commitment to sustainability, performance, and style. With its innovative features, advanced technologies, and robust construction, it stands as a premium choice in modern plumbing solutions, appealing to both eco-conscious consumers and design-savvy homeowners.