Sterling Plumbing CV3-635, 882.00252.00 specifications Station Alarms, Pump Alarms, System Alarms

Page 47

7-2 Alarms

The format for all station alarms is “Station n [alarm text],” for example, “Station 12 receiver low level.” The format for all pump alarms is “Pump n [alarm text].” Any alarm that does not start with “Station” or “Pump” is a system alarm.

The following tables list all alarms alphabetically, together with possible causes. A “critical” alarm is one that causes the affected device to stop.

Note: You can also see a list of alarms and their causes in the controller’s online help. To display this information, touch the color key of statuses in the upper right-hand corner of either the “Station Status” or the “Pump Status” screen, or touch Help at any other screen. When you are finished reviewing the help, touch Return.

Station Alarms

Alarm message

Possible cause

 

Material line is blocked.

 

Vacuum line is blocked.

High vacuum

Convey time is too long (time-fill station only).

Sequence valve has malfunctioned.

 

Vacuum switch has malfunctioned.

 

Note: After you have corrected the cause of this alarm, the alarm will be

 

cleared when the controller has conveyed a full load to this station.

 

Material container is empty.

 

Material line is disconnected from material source.

No convey

Vacuum line is disconnected from station.

Take-off compartment is not adjusted properly.

 

Convey time is too short.

 

Note: As a stopgap measure, you can disable the “no convey” alarm for

 

this station until the problem can be remedied. See pp. 43.

Not assigned (Critical)

Station has not been assigned to a pump

Pump Alarms

Alarm message

Possible cause

Pump failure

Circuit breaker or overload protector has tripped.

(Critical)

Contactor has malfunctioned.

Pump fault

(Function determined by your facility.)

System Alarms

Alarm message

Possible cause

Low battery

Battery for the controller is defective.

Battery for the controller is old and drained.

 

3–Pump 33-Station Controllers

Chapter 7: Troubleshooting

46 of 51

Image 47
Contents SCC 3-Pump 33-Station Controllers Parts and Service Department Shipping Information Table of Contents Maintenance Configurable Settings Contract Department Safety Symbols Used in this Manual SafetyHow to Use This Manual Wear Safety Glasses and Work Gloves General Responsibility ResponsibilityOperator Responsibility Maintenance ResponsibilityReporting a Safety Defect General Description Functional DescriptionModels Covered in This Manual Electrical Features Standard FeaturesOptional Features Mechanical FeaturesFail Safe Operation Safety Devices and InterlocksSafety Circuit Standards Safety Device Lock-OutsMounting the Control Panel InstallationMaking Control Panel Power Drop Wiring Connections UncratingConnecting the Control Panel to the Pump Package Connecting the Control Panel to Vacuum HoppersSetting the Number of Stations and the Number of Pumps SetupSystem Setup Screen Before Setup System Setup Screen Setting Up Alarm SilencesSetting Up Touch Switch Delay Setting Up Pump StagingSetting Up a Single Station Setting Up StationsStation Setup Screen Station Copy Screen Copying Settings from One Station to OthersPage Setting Up a Single Pump Setting Up PumpsPump Copy Screen Copying Settings from One Pump to OthersSetup Password Finishing Setup Setting Up PasswordsOperator Password Initial Startup Reviewing Station Status OperationOverview Basic TasksColor Label Description Pump Status Screen During Operation Reviewing Pump StatusLogging On and Logging Off Password Entry ScreenStarting and Stopping the System Enabling and Disabling Stations and PumpsNavigating among the Station Operator Screens Reviewing and Adjusting Basic Station SettingsAdjusting Convey Time and Dump Delay Activating and Stopping Priority Convey for a Station Reviewing and Resetting a Pump Hour Meter Adjusting Advanced SettingsTransfer To Standby Pump Screen Transferring Stations to a Standby PumpTransfer To Standby Pump Button Reviewing Alarms AlarmsStandby Pump Errors Silencing Alarms Maintenance Options for Station Setup Configurable Settings# attempts before Idle Time Options Options for Pump SetupGeneral Troubleshooting TroubleshootingSystem Alarms Station AlarmsPump Alarms Optional Components WarrantyAppendix Pump 33 station Controller with 6 Display Drawings and DiagramsDC Voltage Spare Parts ListReturned Material Policy AC VoltageController Identification Serial Number Tag Safety Tag InformationWarranty Returns Controller Safety TagsSales Department Service DepartmentTechnical Assistance Contact Information Parts Department

882.00252.00, CV3-635 specifications

The Sterling Plumbing CV3-635,882.00252.00 is a revolutionary addition to home plumbing solutions, designed to enhance efficiency and convenience. This model stands out in the market due to its innovative features, advanced technologies, and sturdy characteristics, making it a reliable choice for homeowners and professionals alike.

One of the main features of the CV3-635 is its high water efficiency. Engineered to reduce water consumption without sacrificing performance, this plumbing fixture is ideal for environmentally conscious users. It is designed to meet or exceed regulatory standards for water flow, ensuring optimal operation while helping to conserve precious resources.

The CV3-635 also incorporates state-of-the-art technology, including SmartFlow technology, which allows for precise water temperature control. This feature ensures that users can enjoy consistent and comfortable water temperatures, eliminating the risk of sudden temperature fluctuations. With a user-friendly interface, adjustments can be made easily, accommodating the needs of every member of the household.

Durability is a key characteristic of the Sterling Plumbing CV3-635,882.00252.00. Constructed with high-quality materials, it resists leaks and corrosion, ensuring a long lifespan. The polished chrome finish not only enhances its aesthetic appeal but also provides added protection against wear and tear, making it a stylish yet practical addition to any bathroom or kitchen.

Installation of the CV3-635 is straightforward, thanks to its user-friendly design. This model is compatible with standard plumbing configurations, allowing for quick setup and minimal disruption. The comprehensive installation guide that accompanies the product ensures that even less experienced users can install it with confidence.

Another notable feature is its noise-reduction technology, which minimizes operational sounds, creating a quieter environment in the home. This is particularly beneficial in multi-story houses where plumbing sounds can disturb lower levels.

The Sterling Plumbing CV3-635,882.00252.00 is not just a plumbing fixture; it is a commitment to sustainability, performance, and style. With its innovative features, advanced technologies, and robust construction, it stands as a premium choice in modern plumbing solutions, appealing to both eco-conscious consumers and design-savvy homeowners.