Chauvet 3P user manual Stacking, Fixture Linking, Data Cabling

Page 11

Setup

Stacking

The COLORado™ 3 can be stacked vertically and horizontally creating a blinder or a strip light. Stack them horizontally to increase intensity of the projection for more distant throws or to use as a blinder effect. The strip light stacking can be used for runway lighting and cycloramas.

Interlocking connectors provide an easy, fast and secure method for stacking units vertically and horizontally

COLORado™ stacked for use as a Blinder or Large Wash Flood

Fixture Linking

You will need a serial data link to run light shows of one or more fixtures using a DMX-512 controller or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support.

The COLORado™ 3 fixtures use 12 channels (maximum) of DMX control.

Important: Fixtures on a serial data link must be daisy chained in one single line. To comply with the EIA-485 standard no more than 32 devices should be connected on one data link. Connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result in deterioration of the digital DMX signal.

Maximum recommended serial data link distance: 500 meters (1640 ft.)

Maximum recommended number of fixtures on a serial data link: 32 fixtures

Data Cabling

To link fixtures together you must obtain data cables. You can purchase CHAUVET certified DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own

COLORado™ 3P User Manual

11

3/17/2009 9:54 AM

Image 11
Contents COLORado 3P Table of Contents Appendix World Wide Web Before You BeginUnpacking Instructions Contact UsLED Expected Lifespan Safety InstructionsIntroduction FeaturesDMX Channel Summary ARC 1 + D ARCProduct Overview Mounting SetupAC Power Data Cabling StackingFixture Linking DM X Data Cable Chauvet Certified DMX Data Cables Setting up a DMX Serial Data LinkAdas Overview COLORado Control Quick SetupOperating Instructions Control OptionsAdas with ID address Menu  Settings  ID address  01 ~Menu  Settings  Adas fader no  DMX-512 addressing with ID addressBlock Application COLORcon setupSingle Row Application Repeat Row Block ApplicationDown Setting the DMX addressControl Panel Functions SETUP, DOWN, UP, DOWN, UP, UP, Down Manual Power ON/OFFMenu Map DMX512 Channel Values Effect Macro Module SelectionRed, Green and Blue Selection Important Notes about Stage 1 ModeModule DMX Mode 1 only when channels 1-7 =DMX Mode Dimmer Stage 2 ModeModule Selection Important Notes about Stage 2 Mode Simplified control of modules using channels 1, 2 DMX Channel Values Pixel Mode DMX Channel Values ARC ModeDMX Channel Values ARC+D Mode COLORado Controller Overview SetupEffect Program Menu MapWash Program Clock SettingsCustom Program Play ScheduleControl via external DMX Activating password modeOFF DMX Primer Returns ProcedureMaintenance AppendixWhite RED Green Blue PhotometricTechnical Support Technical Specifications