Operating Instructions
COLORcon™ setup
1.FIXTURE CONTROL PANEL SETUP
Activate ID addressing in each fixture by setting panel function {ID ON/OFF} to ON. {MENU} {Settings) {ID ON/OFF} [ON]
Set ID addresses in each fixture by setting panel function {ID address} to incremental values. (I.e. 1,2,3,4,5,6,etc…)
{MENU} {Settings} {ID address} [01 ~ 66] It is not necessary to set the DMX address.
2.CONTROLLER SETUP
When using the {Effect program} function, it is necessary to set the {Settings} {Range} setting, which is the quantity of fixtures in series.
{MENU} {Settings} {Range} [ (No. of fixtures) ]
Single Row Application
ID Address: 01 | ID Address: 02 | ID Address: 03 | ID Address: 04 | ID Address: 05 | ID Address: 06 | ||||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
SET | UP | DOWN EXIT |
The figure above shows 6 fixtures connected in series with corresponding addresses. Each fixture has {ID ON} in the fixture’s settings. You must set the {Range} settings in the controller to [006] before accessing {Effect} programs.
Repeat Row Block Application
ID Address: 01 | ID Address: 02 | ID Address: 03 |
ID Address: 01 | ID Address: 02 | ID Address: 03 |
ID Address: 01 | ID Address: 02 | ID Address: 03 |
Block Application
ID Address: 01 | ID Address: 02 | ID Address: 03 |
ID Address: 04 | ID Address: 05 | ID Address: 06 |
ID Address: 07 | ID Address: 08 | ID Address: 09 |
The figure above shows 9 fixtures connected in series. Three rows comprised of 3 fixtures are addressed identically. Each fixture has {ID
ON} in the fixture’s settings. You must set the
{Range} settings in the controller to [003] before accessing {Effect} programs.
SET | UP | DOWN EXIT |
The figure above shows 9 fixtures connected in series with corresponding addresses. Each fixture has {ID ON} in the fixture’s settings. You must set the {Range} settings in the controller to [009] before accessing {Effect} programs.
SET | UP | DOWN EXIT |
COLORado™ 3P User Manual | 16 | 3/17/2009 9:54 AM |