Chauvet 3P user manual Technical Specifications, Technical Support

Page 35

 

Appendix

Technical Specifications

 

WEIGHT & DIMENSIONS

 

Length

22.5 in (570 mm)

Width

7.5 in (190 mm)

Height

8.3 in (210 mm)

Weight

18 lbs (8.2 kg)

POWER

 

Autoswitching

AC100V ~ 240V 50/60 Hz

AC input

IEC 60320 C14

Current draw

(peak <75W @ 120V), (inrush 1.2A @ 120V)

Power Factor

PF 1.00 @ 120V

FUSE

 

Internal (Power Supply)

20mm Glass 4A Fast Blow

LED

 

Quantity

54 Total, (Red 18, Green 18, Blue 18)

LED

1 Watt

PHOTO OPTIC

 

Luminance at 1m (15° lenses, included)

7,270 lux

Luminance at 1m (30° lenses, optional)

2,841 lux

Beam angle with included 15° lenses

15° by 18°

Field angle with included 15° lenses

23° by 34°

Beam angle with optional 30° lenses

22° by 34°

Field angle with optional 30° lenses

45° by 59°

CONTROL & PROGRAMMING

 

Data input

locking 3-pin XLR male socket

Data output

locking 3-pin XLR female socket

Data pin configuration

pin 1 shield, pin 2 (-), pin 3 (+)

Protocols

DMX-512 USITT

DMX Channels

3, 4,9, 10,12

ORDERING INFORMATION

 

COLORado ™ 3P

COLORADO3P

Technical Support

 

Address: Service Dept.

 

3000 N 29th Ct, Hollywood, FL 33020 (U.S.A.)

 

Support (Email): tech@chauvetlighting.com

 

Telephone: (954) 929-1115 - (Press 4)

 

Fax: (954) 929-5560 - (Attention: Service)

 

Website: http://www.chauvetlighting.com

 

COLORado™ 3P User Manual

35

3/17/2009 9:54 AM

Image 35
Contents COLORado 3P Table of Contents Appendix World Wide Web Before You BeginUnpacking Instructions Contact UsLED Expected Lifespan Safety InstructionsIntroduction FeaturesDMX Channel Summary ARC 1 + D ARCProduct Overview Mounting SetupAC Power Data Cabling StackingFixture Linking DM X Data Cable Chauvet Certified DMX Data Cables Setting up a DMX Serial Data LinkAdas Overview COLORado Control Quick SetupOperating Instructions Control OptionsAdas with ID address Menu  Settings  ID address  01 ~Menu  Settings  Adas fader no  DMX-512 addressing with ID addressBlock Application COLORcon setupSingle Row Application Repeat Row Block ApplicationDown Setting the DMX addressControl Panel Functions SETUP, DOWN, UP, DOWN, UP, UP, Down Manual Power ON/OFFMenu Map DMX512 Channel Values Effect Macro Module SelectionRed, Green and Blue Selection Important Notes about Stage 1 ModeModule DMX Mode 1 only when channels 1-7 =DMX Mode Dimmer Stage 2 ModeModule Selection Important Notes about Stage 2 Mode Simplified control of modules using channels 1, 2 DMX Channel Values Pixel Mode DMX Channel Values ARC ModeDMX Channel Values ARC+D Mode COLORado Controller Overview SetupEffect Program Menu MapWash Program Clock SettingsCustom Program Play ScheduleControl via external DMX Activating password modeOFF DMX Primer Returns ProcedureMaintenance AppendixWhite RED Green Blue PhotometricTechnical Support Technical Specifications