Apollo 1650ETL, 1550ETL installation manual Applications

Page 4

APPLICATIONS

The Apollo Model 1550ETL/1650ETL Swing Gate Operator is approved for Vehicu- lar Class I & II usage under UL 325 Guidelines, and is designed to handle swing gates up to 16 feet in length and 600 pounds each. A professional fence or gate dealer is recommended to assure proper installation. Apollo Gate Operators are available only through qualified dealers with an outstanding reputation in the fence and gate industry. These dealers will be able to recommend the proper equipment for particular applications. Apollo Gate Operators are 12 Volt DC (Direct Current) powered. A 12 Volt sealed battery (33 ampere hour minimum) with connecting posts located on the top is recommended. There are several advantages with 12 Volt DC systems:

Low voltage virtually eliminates risk of electrical shock.

Battery powered operators provide up to 200 operations in the event of power outages.

The battery may be recharged with a trickle charger or by solar energy (eliminating the need for costly trenching to remote entrances).

If a trickle charger is used and a standard electrical outlet is not readily available, a licensed electrician will be required for proper electrical hook up.

The following table should be used as a guide for capacity of operation of operators only, additional options may reduce the the daily usage. Please note that the charge capability of solar panels will vary with different geographical locations.

Daily Cycles

1-10

1-20

1-40

1-60

1-80

80+

 

 

 

 

 

 

 

5 watt solar panel

*

 

 

 

 

 

 

 

 

 

 

 

10 watt solar panel

 

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20 watt solar panel (requires 5310 regulator)

 

 

*

 

 

 

 

 

 

 

 

 

30 watt solar panel (requires 5310 regulator)

 

 

 

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

40 watt solar panel (requires 5310 regulator)

 

 

 

 

*

 

 

 

 

 

 

 

1.5 amp battery charger

 

 

 

 

*

 

 

 

 

 

 

 

 

 

 

 

 

 

 

10 amp battery charger

 

 

 

 

 

*

 

 

 

 

 

 

 

 

 

 

 

 

 

Note: Double the amount of solar panels for Dual Gate Operators.

4

Image 4
Contents Installation Manual Contents Important Safety Instructions Applications PRE-INSTALLATION Checklist Consider safety and access options. Recommend if neededParts Identification OptionsVertical position Location of Pivot PointPivot arm Connecting the Actuator s Gate Bracket Installation 1550ETL / 1650ETL Actuator Option Push to Open Installation Rewiring actuator s for push to openTop View Pivot arm sProgramming Instructions 835/836 Control Board Parts Identification GateLink Connector Adjustments Push Buttons Jumpers OFF Optional Device Inputs Apollo Gate Operators, Inc Apollo Gate Operators Receiver Options Symptom Gate moves only a few feet, then stops or reverses Symptom Gate opens OK but after closing, opens back upSymptom Gate surges too much. Does not run smooth Symptom Transmitter works, but not very far Symptom Gate randomly opens, closes, or stops for no reasonSymptom Gate will not open or close Dual BoardsLimited TWO-YEAR Warranty