STEP 2 Actuator Installation

1/2” x 3 1/2” Hex Bolt

1/2” Washer

1/2” Lock Nut

Do not over tighten nut

STEP 3 Control Box Installation

Mount the control box within 4 feet of the pivot arm.

Do not mount the control box where the person using the push button on side of the box can come in contact with the gate. Use mounting hardware capable of supporting the weight of the control box with the battery installed.

Set battery inside of control box with terminals toward the front (Do not use any battery with side terminals).

STEP 4 Connecting the Actuator (s)

Connect actuator cable to the “MASTER” connector on the

 

control board.

 

If a 1650 Dual Operator is being installed and conduit is

 

being used under the drive (recommended), cut the slave

 

(opposite side where control box is mounted) actuator cable

 

about 12” from the white connector. Run the remaining

 

cable across the drive through conduit and up through the

 

control box. Cutoff any excess cable and splice the short

 

piece back to the cable.* Connect to the “SLAVE” connector

SLAVE

on the control board.

MASTER

 

Connect the RED power wire (s) to the battery positive ( + )

 

and the BLACK power wire (s) to the battery negative ( - )

 

*Instead of cutting the slave cable, remove the pins on the plug with a jeweler's common blade screwdriver or appropriate tool (the staples on the actuator shipping carton work great) ,run the cable through the conduit and reinsert the pins into the plug.

8

Image 8
Contents Installation Manual Contents Important Safety Instructions Applications PRE-INSTALLATION Checklist Consider safety and access options. Recommend if neededParts Identification OptionsPivot arm Location of Pivot PointVertical position Connecting the Actuator s Gate Bracket Installation 1550ETL / 1650ETL Actuator Option Push to Open Installation Rewiring actuator s for push to openTop View Pivot arm sProgramming Instructions 835/836 Control Board Parts Identification GateLink Connector Adjustments Push Buttons Jumpers OFF Optional Device Inputs Apollo Gate Operators, Inc Apollo Gate Operators Receiver Options Symptom Gate surges too much. Does not run smooth Symptom Gate opens OK but after closing, opens back upSymptom Gate moves only a few feet, then stops or reverses Symptom Transmitter works, but not very far Symptom Gate randomly opens, closes, or stops for no reasonSymptom Gate will not open or close Dual BoardsLimited TWO-YEAR Warranty