Apollo 1550ETL, 1650ETL installation manual Symptom Transmitter works, but not very far

Page 21

SYMPTOM Gate will open using push button on side of box, but not with transmitter.

1.Code switches do not match. Check that the code switches in the transmitter and the receiver match.

2.Low or dead battery in transmitter. Replace battery.

3.Fuse blown on circuit board. Check fuses on gate control board.

4.Low battery in operator. Battery voltage should be 12 to 14 volts under load.

5.Replace receiver.

Note: Code switches for receiver are inside of receiver. Do not confuse with program switches on control board.

SYMPTOM Transmitter works, but not very far.

Note: Transmission distances will vary according to terrain, obstructions, and electrical interference. The normal range from inside a vehicle is 50-100 feet while 100-150 feet may be obtained from outside the vehicle.

1.Low battery in transmitter. Replace battery.

2.Transmitter malfunctioning. Try a different transmitter.

3.Antenna not making good connection. Be sure center conductor of antenna is penetrating the female connector on the side of the gate box.

4.Reception is being blocked. Raise the height of the antenna using a #244 antenna extension kit.

5.Replace receiver.

SYMPTOM Gate randomly opens, closes, or stops for no reason.

1.Transmitter is stuck on. Check all transmitters, keypads, pushbuttons, etc. for a stuck button.

2.Transmitter and receiver code switches are all down, up, or in the middle. Change at least one switch position in the transmitter and receiver.

3.Push button on side of control box is defective. Disconnect and test.

21

Image 21
Contents Installation Manual Contents Important Safety Instructions Applications Consider safety and access options. Recommend if needed PRE-INSTALLATION ChecklistOptions Parts IdentificationLocation of Pivot Point Vertical positionPivot arm Connecting the Actuator s Gate Bracket Installation 1550ETL / 1650ETL Actuator Option Rewiring actuator s for push to open Push to Open InstallationTop View Pivot arm sProgramming Instructions 835/836 Control Board Parts Identification GateLink Connector Adjustments Push Buttons Jumpers OFF Optional Device Inputs Apollo Gate Operators, Inc Apollo Gate Operators Receiver Options Symptom Gate opens OK but after closing, opens back up Symptom Gate moves only a few feet, then stops or reversesSymptom Gate surges too much. Does not run smooth Symptom Gate randomly opens, closes, or stops for no reason Symptom Transmitter works, but not very farDual Boards Symptom Gate will not open or closeLimited TWO-YEAR Warranty