Jackson Delta 1200 Operating Instructions To Fill Machine with Water, To RUN the Machine

Page 14

SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS

OPERATING INSTRUCTIONS

TO FILL MACHINE WITH WATER:

1.Remove wash tank strainer and place overflow stopper into fitting at the bottom of the wash tank.

2.Open incoming water shut-off valves on cold and hot water lines.

3.Place the power switch to the “FILL” position, machine will automatically fill to the correct level.

4.Check water level, it should be near top of the overflow stopper.

5.Replace wash strainer.

TO RUN THE MACHINE:

1.After filling with water, turn the power switch to the “ON” position, the rack will automatically being to rotate.

2.Place glasses on the rack.

3.When the glasses have completed the cycle, the paddle switch will be activated, turning off the water flow and conveyor rack.

4.Remove the clean glasses which are against the paddle switch.

5.The rack will begin to rotate again.

SHUTDOWN AND CLEANING OF THE MACHINE:

1.Ensure that all ware placed on the rack is able to complete the cycle and is cleaned prior to moving the power switch to the “OFF” position. Shut off the water supply to the unit.

2.Remove the drain boards, rack cylinder and rack. Clean before reinstalling into the machine.

3.Remove the sump and drain tank strainers. Clean completely before reinstalling into the machine.

4.Remove the stand pipe by grasping by the handle and removing from the drain tank. Clean before reinstalling into the machine.

CAUTION: Water in the drain tank may be hot, allow the water to cool down and always remove the stand pipe through the use of the handle. Never place your hand in the water within the drain tank.

5.Remove the curtains and wash using a mild soap and rinse with clear water. Allow to dry completely before reinstalling into the machine.

6.Remove the wash and rinse arms. Inspect them for clogged or obstructed nozzles. Remove end caps and flush the inside of the wash and rinse arms with clean water. Reinstall end caps when completed.

7.Wipe out the inside of the tub, removing any and all debris.

8.Reinstall all components previously removed after they have been allowed to dry.

9.Remove, clean and reinstall upper (wash) and lower (drain) strainers.

Delta 1200 Technical Manual 07610-003-62-15 G

Issued: 10-27-2008 Revised:05-21-2012

9

Image 14
Contents Technical Manual For Jackson ModelsPage Revision Made Applicable Details Date ECN Glasswasher Series Nomenclature for the Models Covered in this ManualTable of Contents Section Specification Information Specification Information Machine Dimensions Section B-BSection INSTALLATION/OPERATION Instructions INSTALLATION/OPERATION Instructions Installation InstructionsElectrical Connections Detergent Control Chemical Dispensing Equipment To Prepare Pumps for Operation Priming Chemical Feeder PumpsTo RUN the Machine Shutdown and Cleaning of the MachineOperating Instructions To Fill Machine with Water Section Preventative Maintenance Preventative Maintenance Preventative MaintenanceSection Troubleshooting USE Extreme Caution When Testing the Machine TroubleshootingCommon Problems Problem Low wash water pressure at wash arm spray nozzles Problem Rinse aid pump not feeding, detergent feeds okay Section Service Procedures Tools Required Service ProceduresPreparation Time RequiredPulling the rubber tube out of the pump Special Parts After Maintenance ActionsSpecial Notes Wash Tank Heater Replacement Removing upper wash strainer Removing the heater nuts Removing the heater gasket Thermostat Replacement None Service Procedures Wash Motor ReplacementCombination wrench After Maintenance Actions Section Parts Section Control BOX Assembly Parts SectionParts Section QTYOuter Shell Assembly Outer ShellParts Section Chemical Feeder Pump Assembly Parts Section Rinse Assembly Wash Assembly Wash and Fill System Wash SystemParts Section Conveyor and Drive System Conveyor Drive SystemParts Section Door Assembly Parts Section Section Electrical Schematics Electrical Schematics