Installation on a Cart
(Carbon Steel and Aluminum Plates)
Installation
Reference letters and numbers in the text refer to Figs.
WARNING
MOVING PARTS HAZARD
Moving parts can pinch or amputate your fingers. When the pump is operating and when raising or lowering the ram, keep
your fingers and hands away from the priming piston and the lip of the pail.
WARNING
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 5.
1.Relieve the pressure.
2.Install the wiper plate (A) onto the pump intake (B), with the wiper plate vent handle (C) facing the front of the cart. Secure by tightening the setscrew (3).
See Fig. 5.
3.The wiper plate is supplied for use with 19 liter (5 gallon) straight sided pails on a ram. It must be modified for use with the pneumatic elevator cart. See steps a and b, following.
a.To use the wiper plate with straight sided pails, the large spacer (19) must be inverted. Working from the bottom, use a screwdriver to pry the spacer loose. Work it upward so it is completely above the flange (D) of the wiper plate. See Fig. 6. Next, by hand, angle the spacer and work it off the plate, pulling it down over the flange and bottom wipers (E). See Fig. 7. Turn the spacer so the large diameter is facing up. Work the spacer up over the wiper plate by hand, so it is completely above the flange (D) of the wiper plate. Working from the top, use a screwdriver to position the spacer between the flange (D) and the wipers
(E). See Fig. 8.
b.To use the wiper plate with tapered pails, the large spacer (19) must be removed. Work- ing from the bottom, use a screwdriver to pry the spacer loose. Work it upward so it is com- pletely above the flange (D) of the wiper plate. See Fig. 6. Next, by hand, angle the spacer and work it off the plate, pulling it down over the flange and bottom wipers (E). See Fig. 7. Save the spacer, as it is required for other applications.
4.Install Cart Accessory Kit 224376. See 308087 for details.
5.Refer to the separate cart and pump manuals for
Maintenance
If the wiper plate does not come out of the pail easily when the pump is being raised, the air assist tube (F), fitting (H), or check valve (21) may be plugged. This prevents air from reaching the underside of the plate to assist in raising it from the pail.
WARNING
To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 5.
Relieve the pressure. Refer to the Parts Drawings on pages