Change Serial Port Settings

Use the Configuration page in the EDI5000 system configuration software to configure the serial port connection as shown in Figure 24.

Figure 24. EDI5000 Serial Port Settings

Setting

Description

Value

 

 

 

Protocol

Select the communication protocol that matches the

AmericanDynamics

 

manufacturer of the matrix system

 

 

 

 

Baud Rate

Baud rate

Use the same baud rate used

 

 

for the matrix system

 

 

 

Data bits

Data bits

8

 

 

 

Stop bits

Stop bits

1

 

 

 

Parity

Parity

None

 

 

 

HW Protocol

This is the serial communication interface used for

RS-232

 

communication between devices

 

 

 

 

Flow Control

This setting controls the rate of data transmission between

None

 

devices; use the default

 

 

 

 

Connected to

This setting must correspond to the actual wiring connections

COM Port 1: Keyboard

 

between the data interface and the matrix system components

COM Port 2: Matrix System

 

 

 

Change General Configuration Settings

Figure 25. EDI5000 Configuration Settings

To change the way the EDI5000 operates, modify the following settings:

Is Primary: This check box is reserved for future use.

Live On Switch: If you configure the EDI5000 data interface to display both live video and recorded video (by selecting the LIVEPLAYBACK option; refer to Display Mode below), the Live On Switch setting determines what viewing mode is displayed when an operator switches to a camera viewed through the data interface. Click this check box to set live video as the default mode. When the check box is cleared, the monitor defaults to playback mode. In a system where you are using Endura cameras for expansion, it is recommended to set live video as the default mode. If LIVEPLAYBACK is not selected in the Display Mode box, the Live On Switch setting is ignored.

Alarm Monitoring: Click this check box to enable the EDI5000 to receive alarms from the Endura system. When configuring alarms in the Endura system, be sure to assign each alarm a unique logical number. Configure a matrix system alarm for each alarm received from the Endura system, using physical numbers for the matrix alarms that match the logical numbers used in the Endura system. Refer to the

24

C2688M-C (12/08)

Image 24
Contents Endura EDI5000-AD2088 Data Interface Page Contents List of Illustrations List of TablesRegulatory Notices Regulatory NoticesRadio and Television Interference Accessories and Power Supplies DescriptionCompatible Products Sample ApplicationsSample System Using Endura to Record Matrix Video Important NOTE. Please ReadCOM Port Indicator COM 1 or COM RS-232 Connectors Front and Rear PanelsInstallation Hardware Installation OverviewParts List Before YOU BeginProduct Serial Number Label Placement Desktop InstallationMounting USER-SUPPLIED PartsWall Mount Installation EDI5000 Data Interface Desktop PlacementRack Mount Installation Tighten the Thumbscrew to Secure the UnitPelco Badge Orientation Tighten Thumbscrew to Secure the UnitConnecting the Matrix System to the EDI5000 Basic Hardware ConnectionsCom Pin Lead RS-232-Data Rx+ Ground RS-232 Data Tx+Important Note Please Read Pin Assignment AD2088 Keyboard EDI5000 COMPower Connection Network ConnectionPower Supply Options Install Bonjour for WindowsBonjour Technology Use Bonjour to Navigate to the EDI5000 Web Interface Renaming EDI5000 Bonjour LogonSoftware Configuration Software Configuration OverviewOptional Configuration Tasks Connect to the System Configuration Software EDI5000 Login Dialog BoxConfigure the Data Interface Settings EDI5000 System Configuration SoftwareSave Changes to the EDI5000 Configuration Change Configuration SettingsChange Serial Port Settings Change General Configuration SettingsSetting Description Value Configure Network Settings Click the Network Settings tabConfigure DVR/NVR Settings Add a Recorder to the EDI5000 Configuration Edit a DVR/NVR Entry in the EDI5000 ConfigurationDelete a DVR/NVR Entry From the EDI5000 Configuration Click a device in the NVR Friendly Name sectionConfigure DECODER-MONITOR Settings Add a Decoder Monitor to the EDI5000 ConfigurationAbout the Decoding Device Edit a Decoder Monitor Entry in the EDI5000 Configuration Click the NTP Settings tabClick Apply to save the setting Click a device in the Decoder-Monitor Friendly Name sectionSoftware Update Options File Support OptionsExport Configuration Settings Exporting EDI5000 Configuration SettingsAdditional Software Features HOW to Sign OUTImport Configuration Settings Click Sign OutFront Panel Indicators OperationReset Button HOW to Operate the EDI5000-AD2088Viewing Video How to Toggle Between Live and Recorded Video Viewing and Controlling VideoPTZ Control Command Key Joystick Controlling Recorded VideoAction Current Mode = Play Current Mode = Pause Fast Forward SpeedsUsing Digital Zoom Rewind SpeedsTroubleshooting Problem Meaning Possible Causes Suggested RemedySpecifications STANDARDS/ORGANIZATIONS C2688M-C 12/08 Product Warranty and Return Information Warranty