Installation

HARDWARE INSTALLATION OVERVIEW

The following steps provide an overview of how to install the data interface:

1.Install all components of the matrix switching system (refer to the matrix system documentation for instructions).

2.Install the EDI5000 data interface, and then make the following connections (instructions are provided in this Installation section):

a.Connect the data interface to the matrix system keyboard.

b.Connect the data interface to the Endura network.

NOTE: If the matrix system includes more than one keyboard, you can install one data interface unit for each matrix keyboard.

3.Install all components of the Endura system and connect all components to the network (refer to the Endura system documentation for instructions).

NOTE: The EDI5000 is compatible with Endura version 1.03 or later components (NVR5000 and SM5000); Endura decoders must be version 1.04.0032 or later.

4.Connect the appropriate Endura devices to the matrix system, as follows (refer to the matrix system documentation and the Endura system documentation for instructions):

Endura recording system: When using Endura to record video from the matrix system, you need the following video connections:

Analog video from each matrix system camera must be looped from the matrix system to Endura encoders (refer to the matrix system documentation for instructions on looping video).

Recorded video from Endura decoders (using the monitor output connector) must be routed to the matrix; use the video input connectors on the matrix system.

Endura expansion system: If you are using Endura to expand the number of cameras that can be viewed in the matrix system, you need an analog connection between each Endura decoder and the matrix system; use the video input connectors on the matrix system.

Be sure that the distance between the Endura device and the matrix system video connectors is less than the maximum distance for the coaxial cable.

Once the hardware installation and device connections are completed, you must configure the data interface software. Refer to Software Configuration on page 20.

BEFORE YOU BEGIN

Since Endura is a network system that requires a continuous amount of bandwidth to transmit live video, always include your network administrator when planning and installing Endura components. In addition, you will need Pelco-approved Endura certification.

PARTS LIST

Qty Description

1EDI5000 data interface

4 Rubber mounting feet

110-pin terminal block

14-pin to 2-pin power adapter

1Pelco badge rotation sticker

1Small flat-tip screwdriver

NOTE: Since power requirements vary by installation, an individual power supply is not included with the data interface. You can purchase either the NET5301PS single unit power supply or the RK5100PS-5U rack mount, which includes a power supply. Refer to Power Connection on page 16 for more information.

C2688M-C (12/08)

9

Image 9
Contents Endura EDI5000-AD2088 Data Interface Page Contents List of Tables List of IllustrationsRegulatory Notices Regulatory NoticesRadio and Television Interference Description Accessories and Power SuppliesCompatible Products Sample ApplicationsImportant NOTE. Please Read Sample System Using Endura to Record Matrix VideoFront and Rear Panels COM Port Indicator COM 1 or COM RS-232 ConnectorsHardware Installation Overview InstallationParts List Before YOU BeginDesktop Installation Product Serial Number Label PlacementMounting USER-SUPPLIED PartsEDI5000 Data Interface Desktop Placement Wall Mount InstallationTighten the Thumbscrew to Secure the Unit Rack Mount InstallationTighten Thumbscrew to Secure the Unit Pelco Badge OrientationBasic Hardware Connections Connecting the Matrix System to the EDI5000Com Pin Lead RS-232-Data Rx+ Ground RS-232 Data Tx+Pin Assignment AD2088 Keyboard EDI5000 COM Important Note Please ReadNetwork Connection Power ConnectionPower Supply Options Install Bonjour for WindowsBonjour Technology Use Bonjour to Navigate to the EDI5000 Web Interface Bonjour Logon Renaming EDI5000Software Configuration Software Configuration OverviewOptional Configuration Tasks EDI5000 Login Dialog Box Connect to the System Configuration SoftwareEDI5000 System Configuration Software Configure the Data Interface SettingsChange Configuration Settings Save Changes to the EDI5000 ConfigurationChange Serial Port Settings Change General Configuration SettingsSetting Description Value Click the Network Settings tab Configure Network SettingsConfigure DVR/NVR Settings Edit a DVR/NVR Entry in the EDI5000 Configuration Add a Recorder to the EDI5000 ConfigurationDelete a DVR/NVR Entry From the EDI5000 Configuration Click a device in the NVR Friendly Name sectionConfigure DECODER-MONITOR Settings Add a Decoder Monitor to the EDI5000 ConfigurationAbout the Decoding Device Click the NTP Settings tab Edit a Decoder Monitor Entry in the EDI5000 ConfigurationClick Apply to save the setting Click a device in the Decoder-Monitor Friendly Name sectionFile Support Options Software Update OptionsExporting EDI5000 Configuration Settings Export Configuration SettingsHOW to Sign OUT Additional Software FeaturesImport Configuration Settings Click Sign OutOperation Front Panel IndicatorsReset Button HOW to Operate the EDI5000-AD2088Viewing Video How to Toggle Between Live and Recorded Video Viewing and Controlling VideoPTZ Control Controlling Recorded Video Command Key JoystickFast Forward Speeds Action Current Mode = Play Current Mode = PauseRewind Speeds Using Digital ZoomProblem Meaning Possible Causes Suggested Remedy TroubleshootingSpecifications STANDARDS/ORGANIZATIONS C2688M-C 12/08 Warranty Product Warranty and Return Information