Video Processor 1 Board
Test Sawtooth Nominal Settings 15. Sawtooth amplitude
Measure at:  | Adjust with:  | 
MP110  | ZR111  | 
  | 
  | 
Required result:
Correct:  | 
  | 
0.2V  | 10µS  | 
100  | 
  | 
90  | 
  | 
10  | 
  | 
0%  | 
  | 
  | VA+1.00V  | 
16.Sawtooth slope
Set sawtooth amplitude to 100% on oscilloscope, measure between 10% and 90% and adjust slope test.
Measure at:
MP110
Adjust with:
R112
Required result:
25 µS
Correct:  | 
  | 
0.2V  | 5µS  | 
100  | 90%  | 
90  | |
10  | 10%  | 
  | |
0%  | 
  | 
  | t+25.0µS  | 
  | 25µS  | 
17.Sawtooth horizontal shift
Set master black level to +10%.
Adjust start sawtooth for 4.5 µS after system blanking.
Measure at:  | Adjust with:  | Required result:  | 
CVBS out  | R108  | 
  | 
  | 
  | 
  | 
Video output
18. Adjust the video output amplitude
Correct:  | 
  | |
0.2V  | 0.2V  | 5µS  | 
100  | 
  | 
  | 
90  | 
  | 
  | 
  | 
  | CVBS  | 
10  | 
  | 
  | 
0%  | 
  | 
  | 
  | t+4.50µS  | 
  | 
  | 4.5µS  | 
  | 
Measure at:
Adjust with:
ZR206 (R)
ZR406 (G)
ZR606 (B)
Required result:
450mV (R) 450mV (G) 450mV (B)
Correct:  | 
  | 
0.1V  | 10µS  | 
100  | 
  | 
90  | 
  | 
10  | 
  | 
0%  | 
  | 
  | VA+450mV  | 
Adjustments  | Technical Manual LDK 20(S) - Studio Camera  |