Video Miscellaneous Board
R-Y amplitude
10. Adjust
Measure at: | Adjust with: | Required result: |
ZR93 | 1400mV | |
|
|
|
Correct:
0.2V10µS
100
90
10
0%
VA+1400mV
11. Adjust
Measure at: | Adjust with: |
ZR94 | |
|
|
Video Mux output
12.Colour bar off.
13.Test sawtooth on.
14.Adjust
Required result: 1400mV
Correct:
0.2V10µS
100
90
10
0%
VA+1400mV
Measure at: | Adjust with: |
ZR200 | |
|
|
15. Adjust
Required result: 700mV
Correct: |
|
0.1V | 10µS |
100 |
|
90 |
|
10 |
|
0% |
|
| VA+700mV |
Measure at: | Adjust with: |
ZR400 | |
|
|
16. Adjust B-Mux output.
Required result: 700mV
Correct: |
|
0.2V | 10µS |
100 |
|
90 |
|
10 |
|
0% |
|
| VA+700mV |
Measure at: | Adjust with: |
ZR600 | |
|
|
Required result:
700mV
Correct: |
|
0.1V | 10µS |
100 |
|
90 |
|
10 |
|
0% |
|
| VA+700mV |
Adjustments | Technical Manual LDK 20(S) - Studio Camera |