Encoder Board PAL
Burst amplitude
19. Adjust the burst amplitude potentiometer to obtain a burst amplitude of 300mV.
Measure at:
CVBS out
Adjust with:
ZR210
Required result:
300mV
Correct: |
|
0.1V | 2µS |
100 |
|
90 |
|
10 |
|
0% |
|
| VA+300mV |
Burst timing
20.Observe waveform monitor or oscilloscope and adjust the burst position so that it is 5.6µS from the leading edge of the line synchronisation.
Measure at:
CVBS out
Adjust with:
ZR209
Required result:
Correct: |
|
50mV | 1µS |
100 |
|
90 |
|
10 |
|
0% |
|
| t+5.6µs 178kHz |
Genlock free-running preset
21.Remove genlock signal from camera.
22.Turn lock range potentiometer ZR215 fully counterclockwise.
23.Observe colour monitor, waveform monitor or vectorscope and adjust oscillator preset potentiometer.
Measure at: CVBS out
Adjust with: ZR216
Required result:
Minimum freerunning speed
Sc-H phase relationship
24.Switch vectorscope to internal synchronisation.
25.Adjust
Measure at:
CVBS out
Adjust with:
ZR217
Required result:
Correct: |
|
| |
% |
|
| VOLT |
120 |
|
|
|
100 | R | cy | 0.7 |
|
| ||
80 | g | MG |
|
| V |
| |
|
|
| |
60 | 75 |
|
|
| 100 | b | 5 |
40 | YL |
| |
| U | 0 | |
|
|
| |
20 | yl | B | |
|
|
| 0 |
20 | G | mg |
|
|
|
| |
43 | r | CY | 0.3 |
|
|
26. Switch off power and return encoder board to its position in the camera.
Adjustments | Technical Manual LDK 20(S) - Studio Camera |