Page 27
TM-4200GE Software
5 GigE Series Camera Serial Commands
You can control the GigE series cameras by serial command either using
TABLE 4. TM/TMC-4200 Command List
Command | Parameter | End of | Ack. Response | Description |
Cmd | ||||
Scan Mode |
|
|
|
|
:SMD | X | <cr> | :o<cr> | Set Preset Scan Area (X=A,B,C,D,T) |
:SMDZ= | X | <cr> | :o<cr> | Set Digital Zoom (X=0,1,2,3) |
:SMDU= | XXXXYYYY | <cr> | :o<cr> | Set Programmable Scan Area |
|
|
|
| (XXXX=0000 - 07FF, YYYY=0001 - |
|
|
|
| 0800) |
:SMD? |
| <cr> | :oMD[X]<cr> | Inquire current scan mode |
|
|
|
| (X=A,B,C,D,T,Z,U) |
Shutter Mode and Shutter Speed |
|
| ||
:MSH= | X | <cr> | :o<cr> | Set Continuous Mode Preset Shutter ( X= |
|
|
|
| 0 - 9) |
:DSH= | XXX | <cr> | :o<cr> | Set Continuous Mode Programmable |
|
|
|
| Shutter ( XXX=000 - total lines) |
:ASH= | X | <cr> | :o<cr> | Set Async Mode Preset Shutter (X=0 - 9, |
|
|
|
| A, B) ( X=0 async no shutter, |
|
|
|
| ( |
|
|
|
| Fixed exposure PIV, X=B PWC PIV) |
:ADS= | XXX | <cr> | :o<cr> | Set Async Mode Programmable Shutter |
|
|
|
| (XXX=000 - 81F) |
:SHR? |
| <cr> | :o[shtr]<cr> | Inquire current shutter mode |
Gain and Offset |
|
|
| |
:MGA= | XXX | <cr> | :o<cr> | Set Master Gain |
|
|
|
| (XXX = 000 - FFF) |
:MGB= | XXX | <cr> | :o<cr> | Set R channel Fine Gain |
|
|
|
| (XXX = 000 - FFF) |
:VRA= | XXX | <cr> | :o<cr> | Set Master Offset |
|
|
|
| (XXX = 000 - FFF) |
:VRB= | XXX | <cr> | :o<cr> | Set R channel Fine Offset |
|
|
|
| (XXX = 000 - FFF) |
:MGA? |
| <cr> | :oMG[XXX]<cr | Inquire Master Gain |
|
|
| > | (XXX = 000 - FFF) |
:MGB? |
| <cr> | :oSG[XXX]<cr> | Inquire R channel Fine Gain (XXX = 000 |
|
|
|
| - FFF) |
:VRA? |
| <cr> | :oMF[XXX]<cr> | Inquire Master Offset |
|
|
|
| (XXX = 000 - FFF) |
:VRB? |
| <cr> | :oSF[XXX]<cr> | Inquire R channel Fine Offset |
|
|
|
| (XXX = 000 - FFF) |