TM-4200GE Hardware

8.2.4Attaching the Camera Lens

The TM-4200GE camera accepts 1.2-inch or larger format size C-mount lenses. To attach the C-mount lens1 to the camera, carefully engage the threads and rotate the lens clockwise until it firmly seats on the mounting ring. Do not force the lens if it does not seat properly. Some lenses with extremely long flange backs may exceed the mounting depth of the camera.

8.2.5Adjustable Back-Focus

Before cameras are shipped, back focus is carefully set using a collimator, oscilloscope and other specialized equipment. While the factory-set focus serves well in most cases, an adjustable back focus makes it possible to improve image sharpness when using lower-cost zoom lenses, custom optics, or in unusual parameters.

There should be an obvious need to refocus the lens before attempting to change the back focus. This is a very exacting task. Some cameras have been returned to the factory to reset the back focus after failed attempts to change the focus by customers. It might be wise to label cameras whose back focus was adjusted.

1.The camera must be connected to a monitor before attempting to adjust the back focus.

2.To back focus the camera, first attach a C-mount lens in the mount. Be certain that the lens is prop- erly seated.

3.Next set the lens focus to infinity (if the lens is a manual iris, set the iris to a high f number while still retaining a well illuminated image).

4.Loosen the three miniature hex set-screws (use a 0.9 mm hex wrench) that lock the focus ring in place (two screws for a CS-mount). Slowly turn the lens and focus ring assembly back and forth until you obtain the best image of the desired object. This sets the back focus. Once the best image is obtained, tighten the focus ring set-screws until they are snug. Do not over-tighten the screws.

Note: Mini-bayonet cameras adapted to C-mount do not have the back focus feature.

FIGURE 52. Back Focus Set-Screw Locations

Loosen the three 2mm screws around the perimeter of the C-mount lens collar (two 2mm screws for a CS-mount) to adjust the back focus. Unless you absolutely must, do not attempt to adjust this focus.

1.C-mount to F-mount and C-mount to K-mount adapters are available for larger format lenses (35mm). Check with local photography dealers for these lens adapters.

Installation

Image 63
Contents TM/TMC-4200GE Progressive Scan Cameras Page JAI Inc CE CompliancePage Table of Contents Introduction Table of ContentsTroubleshooting Table of Contents List of Figures List of FiguresList of Figures List of Tables List of Tables Gigabit Ethernet Camera Interface Software IntroductionScope of the Document Related DocumentsSoftware Installation Before Installing the GigE Series Camera-SDK SoftwareInstalling the Software Scanning for Drivers Uninstalling the SoftwareChange and Remove Buttons Quick-StartSelect Camera Window Connectors ConnectorsPower and Signals Connector Hirose Connector, Pin AssignmentEthernet GigEConfiguring the TM-4200GE Camera SetupConfiguring the TM-4200GE Camera Advanced Configuration Window Integrated GigE Camera Software Configuring the ImagerModes Configuring the Internal Frame GrabberTM-4200GE Software GUI Features Check the Current Camera SettingExposure Control Advanced Configuration Port CommunicationShutter Speed Shutter ModeTM-4200GE Software Scan Mode Programmable ScanUser Programmable Variable Partial Scan Programmable Scan Set Dialog Box R Auto Gain Control TM-4200GE Software Gain SettingsGain GainMemory Pages Look-Up TableFree-Running Mode Externally TriggeredInternally Triggered White Balance Control Color Versions Only TM-4200GE Software Save/Restore Settings to Your Hard DiskTest Pattern TM-4200GE Software Main Menu OptionVersion ExitCamera Outputs Signal HandlingSignal Handling Camera InputsGE Camera Gpio Control Block Gpio Look-Up Table Input Signal Description Label Gpio Label TableGpio Look-Up Table Input Labels Output label Signal Description Pulse GeneratorsGpio Look-Up Table Output Labels Pulse Generator GigE Series Camera Serial Commands GigE Series Camera Serial CommandsTM/TMC-4200 Command List Scan ModeImage Pre-processing Channel BalanceVsub Dual Tap Digital Video Output OrderCommand Parameter End of Cmd Description Command Responses Parameter End of Cmd Description0000=Async no shutter 0001 1000=Async Dual-Tap TM-4200GE AccuPiXEL Series Camera-Control Software IntroductionIntroduction Dual-Tap TM-4200GE AccuPiXEL Series Camera-Control SoftwareAccuPIXel Setup screen TM/TMC-4200GE Camera Using the GigE modeMain DualTap AccuPiXEL Window GUI FeaturesOperating The Control Software Introduction Scan Area drop down box Scan AreaOffset Voltage Gain ControlClick on the option button to set the preferred option Video DepthPositive or Negative LUT Selection LUT Look-Up TableDual-Tap TM-4200GE AccuPiXEL Series Camera-Control Software Save PasswordEeprom LoadDual-Tap TM-4200GE AccuPiXEL Series Camera-Control Software Hardware Introduction Hardware IntroductionProduct Description TM-4200GE HardwareFeatures Unpacking Instructions InstallationAccessories and Options Getting StartedPin Connector Camera SetupConnector Pin Configurations 2 a 12-Pin ConnectorPower Supplies and Power Cable Setup Ethernet ConnectorPower Supplies 12P-02S Interface Cable Pin# Lead Color Function JAI Inc. Power CablesBuilding Your Own Power Cable Attaching the Power Cable to the ConnectorTM-4200GE Hardware Attaching the Camera Lens Adjustable Back-FocusOperation Preset Scan AreaOperation Progressive ScanningTM-4200GE Hardware Programmable Scan Area Bayer Full Scan Area 2x2 BinningX2 Binning Sub-sampling Digital ZoomSub-sampling Digital Zoom TM-4200GE Hardware Sub-sampling Digital Zoom Scan Area Start Points Bayer Color Filter Color VersionsBayer Color Filter Array CFA TM-4200GE Hardware Color Filter ArraySync and Data TM-4200GE Hardware Starting Pixel ConfigurationExample of TMC-4200GE Same as TM-4200GE Camera FunctionsScan Mode TM-4200GE Hardware Timing ChartElectronic Shutter Interpolation SoftwareColor Interpolation Electronic Preset Shutter TM-4200GE Hardware Preset ShutterProgrammable Exposure-Continuous Mode Asynchronous No Shutter ModeExternal Trigger Timing Asynchronous Programmable Exposure ModeAsynchronous Programmable External Trigger Pulse Width Control ModePulse Width Control Trigger Particle Imaging Velocimetry Fixed Exposure ModePWC PIV Timing Table Asynchronous Mode Chart TM-4200GE Hardware PWC PIV ModeProgrammable Look-Up Table LUT and Knee Control Dynamic Range ControlExternal Sync and Pixel Locking Camera Timing ChartsArea Clock Scan Data Horizontal pixelsSec Lines External HD Locking and External VD ResetAsync Reset Async Reset Timing Scan AH lines Area AI lines Lines ΜsecSymptom Dark Video TroubleshootingProblems and Solutions Symptom No VideoTM-4200GE Hardware Symptom Video does not Display Properly Symptom Notebook Computer Driver Installation ProblemsInformation and Support Resources Appendix SpecificationsTM-4200GE Camera Specifications Table AppendixPhysical Dimensions TM-4200GE Hardware 11.1.1 TM-4200GE Physical DimensionsSpectral Response TM-4200GE Hardware Spectral ResponseAppendix Page W . j a i . c o m