Cautions in the Start/Stop Trigger Mode.

1. The input of ext. VD signal must be given continuously to synchronize with int. VD signal. It is not possible to input ext. VD signal randomly.

2. The exposure start may delay up to 1H max., when the falling edge of ext. trigger pulse is not synchronized with the falling edge of ext. HD signal. To avoid this 1H jitter and delay, the falling edge of the ext. trigger pulse should be synchronized within 4.4 usec. to the HD pulse. It can be the ext. HD input or the internal HD output.

Shown under cautions in Edge Pre-select Mode page 7.

3. In this mode, the ext. trigger has to be TTL level (2.0 to 5.0 V). It cannot be 75 Ohm terminated. The duration should be more than 1 H negative going. >64 µsec. and < 1 msec. The input is AC coupled.

4. If the ext. VD input and ext. HD input are from a source with TTL level, set SW2-1 and SW2-2 on PK8057 board OFF for non-terminated. SW2-1 for ext. HD signal, SW2-2 for ext. VD signal. See “7.2 SW2 on PK8057 Board”.

5. EachExscanningt.Trg. mode requires the following number of external trigger pulses: - 2:1 interlaced:VD 2 external trigger pulses per frame

- Non-posureinte laced: 1 external1 trigger pulse per field2 a) IntimeVideorlaced mode (Framet1 accumulation mode) t1

b) 2:1ExtimeVideotposure.TrgInterlacedVD. mode1 (Field accumulation mode)2

c) NonExtimeVideotposure.TrgVD-interlace.moded1 (Field accumulation mode)

- 11 -

Image 12
Contents CV-M50 Declaration of Conformity Table of Contents Standard Composition Main Features GeneralLocations and Functions Pin Multi-connector DC-IN/SYNC Pin Multi-connector TriggerPin Assignment Input/Output of HD/VD Signal Normal Shutter ModeExternal Trigger Mode Functions and OperationsCV-M50 EIA Non-interlaced / Field accumulation mode Edge pre-select mode for non-interlace onlyCV-M50 Ccir Non-interlaced / Field accumulation mode Pulse Width Control ModePulse width control mode for non-interlace only Start/Stop Trigger Mode CV-M50 Long Time Exposure Mode EIA CcirCV-M50 Mode Setting Table for SW 1 SettingTable for Shutter Time SW2 on PK8057 Board Jumper Settings Pixel Clock OutputLocation of SW2 and Jumpers Board PK8054 Side B Board PK8057 Side aAdjustment of Video Signal Output Level 126.02 External AppearanceSpecifications Spectral SensitivityPrecautions Typical CCD CharacteristicsAppendix Users Mode Settings Users Modifications User’s RecordCamera type CV-M50 Scanning system Revision Revision F Serial No2700-11083E F3