JAI CV-M50 Ccir Non-interlaced / Field accumulation mode, Pulse Width Control Mode

Page 9

CV-M50

CV-M50 CCIR (Non-interlaced / Field accumulation mode)

Edge pre-select mode (for non-interlace only)

 

 

CCIR : 1H = 64s

 

TRIG

 

 

 

 

1H

TRIG in

 

1H more

 

 

 

 

 

EXT HD

 

 

 

 

 

 

 

INT HD

 

 

 

 

 

 

 

INT VD

 

 

 

 

 

 

 

1.5H

7.5H

 

 

7.5H

6.5H

1.5H

7.5H

EEN

 

 

 

 

 

 

 

Exposure time

 

16.5H

 

 

Exposure time

 

0.5H

0.5H

 

 

 

 

 

 

 

WEN

9H

7.5H

10H

 

14H

 

 

 

 

 

 

CCD out

 

 

 

Effective pixels

 

 

 

 

 

 

 

 

 

 

 

 

 

 

No.10 to 251

 

 

 

Video out

 

25H

 

287H

25H

 

 

 

 

 

 

 

 

 

Blanking

 

Effective video

Blanking

 

 

6.3.2. Pulse Width Control Mode

The pulse width control mode will only work in non-interlaced field accumulation mode.

The exposure is controlled by the low period of the ext. trigger pulse. The CV-M50 starts the exposure at the first HD pulse after the falling edge of the ext. trigger pulse. The exposure ends at the first HD pulse after the rising edge of the ext. trigger. The Shutter can be controlled to be within the range from >1H (>64 usec.) to <60 msec. The AC coupling causes the upper limit.

EEN (Exposure ENable) pulse and WEN (Write ENable) pulses are generated and output from the camera.

The EEN pulse indicates the exposure time. The EEN pulse is output from pin 2 of the 6-pin multi connector. The signal level is 4.0 Vp-p from a 75 Ohm source.

The WEN pulse indicates the time period of the effective video signal output and is useful for the timing and interfacing of external devices such as frame grabbers. The WEN pulse is output from pin 6 of the 6- pin multi connector. The signal level is 4.0 Vp-p from a 75 Ohm source

The video must be read out before a new trigger can be applied. The interval between trigger pulses must be longer than the time for 1 field + the shutter time. It is the limit for the field rate.

To use this mode

Set:

SW1-1, 2 and 3 to OFF

 

SW1-4 to ON for ext. trigger shutter

 

SW1-5 to OFF for field accumulation

 

SW1-6 to ON for non-interlaced

 

JP12 on PK8057 to OPEN

Input:

Ext. trigger to pin 5 on 6-pin multi connector.

 

Ext. HD to pin 6 on 12-pin multi connector. (If used).

 

75 Ohm termination is done with SW2-1 (HD) and SW2-2 (ext.trigger) on PK8057 board.

Refer to Timing Chart and Cautions on next page.

Detailed switch and jumper setting is described in “7. Mode Setting”.

For connections see “5. Pin Assignment”.

- 8 -

Image 9
Contents CV-M50 Declaration of Conformity Table of Contents General Standard Composition Main FeaturesLocations and Functions Pin Multi-connector DC-IN/SYNC Pin Multi-connector TriggerPin Assignment Normal Shutter Mode Input/Output of HD/VD SignalExternal Trigger Mode Functions and OperationsEdge pre-select mode for non-interlace only CV-M50 EIA Non-interlaced / Field accumulation modePulse Width Control Mode CV-M50 Ccir Non-interlaced / Field accumulation modePulse width control mode for non-interlace only Start/Stop Trigger Mode CV-M50 EIA Ccir Long Time Exposure ModeCV-M50 Mode Setting Table for SW 1 SettingTable for Shutter Time SW2 on PK8057 Board Pixel Clock Output Jumper SettingsBoard PK8054 Side B Board PK8057 Side a Location of SW2 and JumpersAdjustment of Video Signal Output Level External Appearance 126.02Spectral Sensitivity SpecificationsPrecautions Typical CCD CharacteristicsAppendix User’s Record Users Mode Settings Users ModificationsCamera type CV-M50 Scanning system Revision Revision F Serial No2700-11083E F3