6. Functions and Operations
6.1. Input/Output of HD/VD Signal
6.1.1. Input of External HD/VD Signal
As factory setting the camera can be synchronized by external HD/VD signals. The signal level must be 4.0V
If no ext. HD is connected, the camera will switch to the internal
6.1.2. Output of Internal HD/VD Signal
The internal HD/VD output is 4.0V
To select this mode, see instructions in “7. Mode Setting”.
6.2. Normal Shutter Mode
When trigger select
The shutter time setting is shown in “7.1.3. Table for Shutter Time”.
6.3. External Trigger Mode
External trigger mode of
1Edge
2Pulse width control mode. (Exposure control by the low period of the ext. trigger)
3Start/Stop trigger mode. (Exposure start by the ext. trigger and end by the ext. VD signal)
4Long time exposure mode. (Exposure control by the interval of the ext. VD signal)
The trigger input is AC coupled, so there is a maximum pulse width for the trigger pulse about 60 msec. The signal level must be 4.0V
The following describes the details of each trigger mode.
6.3.1. Edge Pre-select Mode
The edge
In this mode, the EEN (Exposure ENable) pulse and WEN (Write ENable) pulses are generated and output from the camera. The EEN pulse indicates the exposure time and can be used to control the illumination such as strobe light. The EEN pulse is output from pin 2 of the
The WEN pulse indicates the time period of the effective video signal output, and is useful for the timing and interfacing of external devices such as frame grabbers. The WEN pulse is output from pin 6 of the 6- pin multi connector. The signal level is 4.0
The video must be read out before a new trigger can be applied. The interval between trigger pulses must be longer than the time for 1 field + the shutter time. It is the limit for the field rate.
- 6 -