JAI CV-M50IR operation manual SW2 on PK8057 Board

Page 16

CV-M50IR

7.1.4. Ext. Trigger Shutter Mode

When trigger select SW1-4 is ON. The camera is in ext. trigger shutter mode. The SW1-1, SW1-2 and SW1- 3 are for selecting the shutter speed. The range is from OFF to 1/10,000 second in 8 steps. For each external trigger pulse, the camera will make an exposure with the selected shutter speed.

The shutter time setting is shown in “7.1.3. Table for Shutter Time”.

7.1.5. Trigger Select

SW1-4 is will select the camera operation mode.

OFF is normal mode, where the camera is running continuously.

ON is the ext. trigger shutter mode. Here the external trigger pulse will start the exposure.

7.1.6. CCD Accumulation

SW1-5 will select the CCD accumulation mode.

OFF is field accumulation. It is used for moving objects.

ON is frame accumulation. It is for still objects.

7.1.7. Scanning System

SW1-6 will select the scanning system.

OFF is 2.1 interlaced. It will follow the EIA or CCIR standard for interlaced scanning. ON is non-interlaced.

In EIA the non-interlaced output is continuous ODD field. In CCIR the non-interlaced output is continuous EVEN field.

If the camera is ext. HD/VD synchronized with a non-interlaced sync, SW1-6 be in ON position.

7.1.8. Gamma Correction

SW1-7 will select the gamma correction.

OFF is gamma 1.0. It is linear. Recommended for machine vision and image processing. ON is gamma 0.45. It is non-linear.

7.1.9.Gain Control SW1-8 is for gain select.

OFF is manual gain. Here the gain can be controlled by the GAIN potmeter on the rear panel.

ON is the AGC mode. Here the gain is adjusted automatically. The AGC level can be adjusted by VR3 on PK8056 board. See “8. Adjustment of Video Signal Output Level”.

7.2. SW2 on PK8057 Board

This switch is to select 75 Ohm termination or TTL for ext. HD and ext. VD.

SW2-1 is for HD signal.

SW2-2 is for VD signal, or for ext. trigger in.

ON is 75 Ohm terminated. (Factory setting).

OFF is TTL level.

H D VD

ON

12

O F F

S W 2

- 15 -

Image 16
Contents CV-M50IR Declaration of Conformity Table of Contents Standard Composition Main Features GeneralLocations and Functions Pin Multi-connector Trigger Pin Multi-connector DC-IN/SYNCPin Assignment Input/Output of HD/VD Signal Normal Shutter ModeExternal Trigger Mode Functions and OperationsCV-M50 EIA Non-interlaced / Field accumulation mode Edge pre-select mode for non-interlace onlyCV-M50 Ccir Non-interlaced / Field accumulation mode Pulse Width Control ModePulse width control mode for non-interlace only Start/Stop Trigger Mode CV-M50IR Long Time Exposure Mode EIA CcirCV-M50IR Table for SW 1 Setting Mode SettingTable for Shutter Time SW2 on PK8057 Board Jumper Settings Pixel Clock OutputLocation of SW2 and Jumpers Board PK8054 Side B Board PK8057 Side aAdjustment of Video Signal Output Level 126.02 External AppearanceSpecifications Spectral SensitivityTypical CCD Characteristics PrecautionsAppendix Users Mode Settings Users Modifications DisclaimerUser’s Record Camera type CV-M50 Scanning system2700-11083E F3