e) Data frame error (Master transmission)

Slave

ENQ code (05H)

2)

ACK code (06H)

4)

Send data (ASCII code)

 

 

Send data (ASCII code)

 

Send data (ASCII code)

 

Send data (ASCII code)

1) Session starts when ENQ is sent from master to slave.

Master

1)

3)

3 seconds elapse

5)

3 seconds elapse

3 seconds elapse

6)

2)Slave acknowledges by returning ACK to master.

3)Master sends data.

4)For some reason, slave does not receive data.

5)Master does not receive acknowledgment to the send code and repeats the sequence every 3 seconds for 3 times.

6)If unsuccessful after 3 attempts, master aborts the sequence and ends communication.

6

Image 6
Contents KP-FD30 remote control protocol Rev.1 Transmission from master normal process Master reads data normal process Slave Slave Master Slave Slave Master Text data Data KP-FD30 remote control command table Rev.1 Preset Variabl AES EXT TIG Slow Shutter AES Normal Fast Chroma Gain 00-FF Gamma Charcter Code ~ 7D ? 3F # A2 + 2B Space 7F , 2C = 3D ’27 Read Command Read data Status Area Data Special command For adjustment of a factory OFF Read Command Read data