Hitachi KP-FD30 specifications Gamma

Page 14

15-July-2004

Item

 

STX

 

 

TEXT data

 

 

 

 

ETX

SUM

 

 

 

 

 

Status

ID

Area

R.No

 

Data

 

 

 

GAMMA

 

OFF (γ=1.0)

02

01

FF

01

14

00

 

00

00

03

27

 

 

 

ON (γ=0.45) (*)

02

01

FF

01

14

01

 

00

00

03

26

Video Polarity

 

POSITIVE (*)

02

01

FF

01

01

00

 

00

00

03

2B

 

 

 

NEGATIVE

02

01

FF

01

01

01

 

00

00

03

2A

H Phase for EXT. HD/VD

Min

02

01

FF

01

0B

00

 

00

00

03

1A

 

 

 

02

01

FF

01

0B

**

 

00

00

03

**

 

 

 

Mid (*)

02

01

FF

01

0B

80

 

00

00

03

12

 

 

 

02

01

FF

01

0B

**

 

00

00

03

**

 

 

 

Max

02

01

FF

01

0B

FF

 

00

00

03

EE

OUTPUT

 

VBS,Y/C

02

01

FF

01

46

00

 

00

00

03

22

 

 

 

R,G,B (*)

02

01

FF

01

46

01

 

00

00

03

21

SYNC/HD OUT

 

SYNC (*)

02

01

FF

01

47

00

 

00

00

03

21

 

 

 

HD

02

01

FF

01

47

01

 

00

00

03

20

SYNC ON G

 

OFF (*)

02

01

FF

01

48

00

 

00

00

03

20

 

 

 

ON

02

01

FF

01

48

01

 

00

00

03

1F

LENS TYPE

 

MANUAL (*)

02

01

FF

01

40

00

 

00

00

03

28

 

 

 

AUTO

02

01

FF

01

40

01

 

00

00

03

27

CAMERA RESET

 

 

02

01

FF

01

4F

00

 

00

00

03

12

CAMERA TITLE MODE

 

OFF (*)

02

01

FF

01

1D

00

 

00

00

03

17

 

 

 

TOP

02

01

FF

01

1D

01

 

00

00

03

16

 

 

 

BOTTOM

02

01

FF

01

1D

02

 

00

00

03

15

INPUT CHARACTER

 

1st & 2nd characters

02

01

FF

01

1E

**

 

**

00

03

**

 

 

3rd & 4th characters

02

01

FF

01

1F

**

 

**

00

03

**

 

 

5th & 6th characters

02

01

FF

01

20

**

 

**

00

03

**

 

 

7th & 8th characters

02

01

FF

01

21

**

 

**

00

03

**

 

 

9th & 10th characters

02

01

FF

01

22

**

 

**

00

03

**

 

 

11th & 12th characters

02

01

FF

01

23

**

 

**

00

03

**

 

 

13th & 14th characters

02

01

FF

01

24

**

 

**

00

03

**

 

 

15th & 16th characters

02

01

FF

01

25

**

 

**

00

03

**

 

 

17th & 18th characters

02

01

FF

01

26

**

 

**

00

03

**

 

 

19th & 20th characters

02

01

FF

01

27

**

 

**

00

03

**

 

 

21st & 22nd characters

02

01

FF

01

28

**

 

**

00

03

**

 

 

23rd & 24th characters

02

01

FF

01

29

**

 

**

00

03

**

**: Note: Refer to the character-code table for the symbol “ ** “.

(*): Factory setting

5

Image 14
Contents KP-FD30 remote control protocol Rev.1 Transmission from master normal process Master reads data normal process Slave Slave Master Slave Slave Master Text data Data KP-FD30 remote control command table Rev.1 Preset Variabl AES EXT TIG Slow Shutter AES Normal Fast Chroma Gain 00-FF Gamma Charcter Code ~ 7D ? 3F # A2 + 2B Space 7F , 2C = 3D ’27 Read Command Read data Status Area Data Special command For adjustment of a factory OFF Read Command Read data
Related manuals
Manual 2 pages 1.51 Kb