Hitachi KP-FD30 specifications Data

Page 9

15-July-2004

b)Read (receive) data (slave to master)

1)Command data are converted into ASCII code and transmitted.

2)Comms byte quantity is 10.

3)Comms data format (transmission sequence)

STX

Text data

 

 

10 bytes

ETX

SUM

Comms data description

STX

: Code indicating start of text.

1 byte (02H)

Text data

: Transmit / receive data.

6 byte (ASCII code)

ETX

: Code indicating end of text.

1 byte (03H)

SUM

: XOR result (FFH) of adding STX, Text data and ETX. 2 byte

4) Text data details (transmission sequence)

Data

6 bytes

Text data details (transmission sequence)

 

Data (note)

 

: Sets data to be transmitted.

2 bytes x 3 (ASCII code)

9

Image 9
Contents KP-FD30 remote control protocol Rev.1 Transmission from master normal process Master reads data normal process Slave Slave Master Slave Slave Master Text data Data KP-FD30 remote control command table Rev.1 Preset Variabl AES EXT TIG Slow Shutter AES Normal Fast Chroma Gain 00-FF Gamma Charcter Code ~ 7D ? 3F # A2 + 2B Space 7F , 2C = 3D ’27 Read Command Read data Status Area Data Special command For adjustment of a factory OFF Read Command Read data