Hitachi KP-FD30 specifications Text data

Page 8

15-July-2004

(4)Comms command Text data format

a)Send data and read command data (master to slave)

1)Command data are converted into ASCII code and transmitted.

2)Comms byte quantity is 18.

3)Comms data format (transmission sequence).

STX

Text data

ETX

SUM

18 bytes

Comms data description

STX

: Code indicating start of text.

1 byte (02H)

Text data

: Transmit / receive data.

14 byte (ASCII code)

ETX

: Code indicating end of text.

1 byte (03H)

SUM

: XOR result (FFH) of adding STX, Text data and ETX. 2 byte

4) Text data format details (transmission sequence).

Status

ID no.

Area

address

Relative no.

Data

14 bytes

Text data details

Status

: Transmission data status.

2 bytes (ASCII code)

 

Used for EEPROM write

(0: write absent, 1: write present)

ID no.

: Identification (camera ID) number set by user.

However, ID no. FFH is global address and all data are changed. 2 bytes (ASCII code)

Area address

:Sets number (0 to 255) for each adjustment item. 2 bytes (ASCII code)

Relative no.

:Sets number determined by each area address. 2 bytes (ASCII code)

Data (note)

: Sets data to be transmitted.

2 bytes x 3 (ASCII code)

8

Image 8
Contents KP-FD30 remote control protocol Rev.1 Transmission from master normal process Master reads data normal process Slave Slave Master Slave Slave Master Text data Data KP-FD30 remote control command table Rev.1 Preset Variabl AES EXT TIG Slow Shutter AES Normal Fast Chroma Gain 00-FF Gamma Charcter Code ~ 7D ? 3F # A2 + 2B Space 7F , 2C = 3D ’27 Read Command Read data Status Area Data Special command For adjustment of a factory OFF Read Command Read data