Hitachi specifications KP-FD30 remote control command table Rev.1

Page 10

15-July-2004

KP-FD30 remote control command table (Rev.1)

1)Standard command

a)Write command (Set data)

 

 

 

Item

 

STX

 

 

TEXT data

 

 

 

 

ETX

SUM

 

 

 

 

 

 

 

Status

ID

Area

R.No

 

Data

 

 

 

Auto Light Control Mode (ALC)

AVE (*)

02

01

FF

01

3A

00

 

00

00

03

18

 

 

 

 

 

AREA

02

01

FF

01

3A

01

 

00

00

03

17

 

 

 

 

 

PEAK/AVE

02

01

FF

01

3A

00

 

00

00

03

16

Area of Light measurement

NO.1 (*)

02

01

FF

01

1C

00

 

00

00

03

18

AREA SELECT (ALC: AREA)

NO.2

02

01

FF

01

1C

01

 

00

00

03

17

● Image

 

 

 

NO.3

02

01

FF

01

1C

02

 

00

00

03

16

 

 

 

 

 

NO.4

02

01

FF

01

1C

03

 

00

00

03

15

 

6

5

4

 

 

NO.5

02

01

FF

01

1C

04

 

00

00

03

14

 

 

 

 

 

 

 

2

1

3

 

 

 

NO.6

02

01

FF

01

1C

05

 

00

00

03

13

 

 

 

 

 

 

 

7

8

9

 

 

 

NO.7

02

01

FF

01

1C

06

 

00

00

03

12

 

 

 

 

 

NO.8

02

01

FF

01

1C

07

 

00

00

03

11

 

 

 

 

 

 

 

 

 

 

 

NO.9

02

01

FF

01

1C

08

 

00

00

03

10

Ratio of Peak & Average

0/100 (*)

02

01

FF

01

39

00

 

00

00

03

20

(ALC :PK/AV)

 

 

 

15/ 85

02

01

FF

01

39

01

 

00

00

03

1F

 

 

 

 

 

30/ 70

02

01

FF

01

39

02

 

00

00

03

1E

 

 

 

 

 

50/ 50

02

01

FF

01

39

03

 

00

00

03

1D

 

 

 

 

 

75/ 25

02

01

FF

01

39

04

 

00

00

03

1C

 

 

 

 

 

100/ 0

02

01

FF

01

39

05

 

00

00

03

1B

Video Level (ALC: LEVEL)

Min

02

01

FF

01

0C

00

 

00

00

03

19

[ 00–FF ]

 

 

 

02

01

FF

01

0C

**

 

00

00

03

**

 

 

 

 

 

Mid (*)

02

01

FF

01

0C

80

 

00

00

03

11

 

 

 

 

 

02

01

FF

01

0C

**

 

00

00

03

**

 

 

 

 

 

Max

02

01

FF

01

0C

FF

 

00

00

03

ED

Auto Gain Control Mode (AGC)

OFF (*)

02

01

FF

01

06

00

 

00

00

03

26

 

 

 

 

 

ON

02

01

FF

01

06

01

 

00

00

03

25

FIX. GAIN (AGC: OFF) [00-FF]

Min (*)

02

01

FF

01

2D

00

 

00

00

03

16

FIX. GAIN(dB) = 0.132 x DATA

02

01

FF

01

2D

**

 

00

00

03

**

 

 

 

 

 

Max

02

01

FF

01

2D

88

 

00

00

03

06

AGC LIMIT (AGC: ON) [00-FF]

Min

02

01

FF

01

2F

00

 

00

00

03

14

AGC LIMIT(dB) = 0.132x DATA

02

01

FF

01

2F

**

 

00

00

03

**

 

 

 

 

 

Max (*)

02

01

FF

01

2F

88

 

00

00

03

04

(*): Factory setting

1

Image 10
Contents KP-FD30 remote control protocol Rev.1 Transmission from master normal process Master reads data normal process Slave Slave Master Slave Slave Master Text data Data KP-FD30 remote control command table Rev.1 Preset Variabl AES EXT TIG Slow Shutter AES Normal Fast Chroma Gain 00-FF Gamma Charcter Code ~ 7D ? 3F # A2 + 2B Space 7F , 2C = 3D ’27 Read Command Read data Status Area Data Special command For adjustment of a factory OFF Read Command Read data
Related manuals
Manual 2 pages 1.51 Kb