Haier AU282XHERA, AU342XHERA installation manual Wiring work

Page 16

Wiring work

Crimp connection method for connection wire

After connection,the wire must be fastened by wire cover. The wire cover shall press on the protection coat of the connection wire,as shown in right top figure.

Note:When connecting the wiring,confirm the terminal number of indoor and outdoor units carefully. Incorrect wiring will damage the controller of air conditioner or the unit can not operate.

3.Wiring method of outdoor unit: Power line

Remove the repair board of the outdoor unit and loosen the wire cover A,then put the live wire, neutral wire and grounding wire through the wire cover ,and connect them to terminal block correspon

dingly. After connection, fasten wire cover to its previous state. Communication wire of indoor unit.

Loosen wire cover , put the communication wire through the wire cover B, and connect them to terminal block correspondingly. After connection, fasten wire cover B to its previous state. Note: Power line and communication wire are provided by consumers themselves.

Terminal block

Cord anchorage A

Cord anchorage B

Valve cover

4. Wiring method of indoor unit

Loosen wire cover and connect the power line and communication wire of indoor unit to the terminal correspondingly.

Note:

When connecting power line to power supply terminal, please pay attention to the following items:

Do not connect the power line with different dimensions to the same connection wire end. Improper contact will cause heat generation.

Do not connect the power line with different dimensions to the same grounding wire end. Improper contact will affect protection.

Keep a proper distance between the communication wire and the power line. Otherwise, abnormal

communication will occur because of disturbance. And also, the communication wires should be shielded wire, and the shield cover should be grounded on the outdoor unit.

Do not connect the power line to the connecting end of communication wire. Incorrect connection will cause damage to the connected unit.

14

Image 16
Contents Outdoor Unit Installation Manual Contents Disposal of the old air conditioner Specifications Safety precautions Choose the installation place Installation accessoriesInstallation dimensionsmm Installation drawings of indoor and outdoor units Matching of the indoor and outdoor units For AU342XHERA Power source Limitations on the installationDescriptions Standard Maximum Refrigerant piping work Too outside Way valve Valve rod cap Service port cap Purging method to use vacuum pumpWiring work Correct Pressing Wrong Pressing Terminal Block ClampsWiring work Indoor unit a Test running Items to confirmFailure State Trouble Possible Reasons Code Haier Group