Hitachi BE-IR31, BE-IR30 manual Function setting and changes, Gamma response

Page 16

11. Function setting and changes

11-2 Gamma response

The factory setting is gamma on. If necessary , the gamma response can be changed as follows.

Change the gamma response by changing the chip part.

 

Gamma(γ )response

R217

R218

R219

 

 

 

ON

Absent

0

0

Factory setting

 

OFF

0

Remove

Remove

 

 

0: Part code

RME1784

 

 

 

 

Description

ERJ3GEYJ0R00V

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Location of chip capacitors (Main board side B)

BE-IR30 / 31

15

Image 16
Contents Infrared B/W Camera Module Operation Guide Table of Contents Specifications IntroductionGeneral Composition.Specifications Auto electronic shutter BE-IR30 BE-IR30 External view External view Optical dimensions Installation Two 2.5 mm DiaTypical connection BLK GRN YEL REDTypical connection External sync BE-IR31 Function setting and changes AGC on / offFunction setting and changes Gamma responseAuto electronic shutter on / off Changes to fixed shutter mode FixedBE-IR30 external sync BE-IR31 internal sync HD and VD output BE-IR30 only Options Options BE-IR30C/31C and CS mount adapter option combined dimensions Spectral sensitivity typical example U t i o n