4.Specifications
2) | Sensing area | EIA : 6.00(H)×4.96(V)mm | |||
|
| CCIR : 6.00(H)×4.96(V)mm | |||
3) | Signal format | Conforming to EIA or CCIR. | |||
4) | Scanning system | 2:1 interlaced |
| ||
5) | Hor. scanning frequency | EIA : | 15.734 kHz |
| |
|
| CCIR : | 15.625 kHz | ||
6) | Vert. scanning frequency | EIA : | 59.94 Hz |
| |
|
| CCIR : | 50 Hz |
| |
7) | Sync system | Internal sync | |||
|
| ||||
8) | External sync input | HD & VD : 5V | |||
|
| Input impedance : | 1kΩ | ||
|
| Frequency deviation : ± 1% | |||
9) | Video output | 1.0 | |||
|
| Video component : | 0.7 | ||
|
| Sync component : 0.3 | |||
10) | Resolution | EIA : | 570(H)×380(V) TV lines | ||
|
| CCIR : | 560(H)×380(V) TV lines | ||
11) | Signal to noise ratio | 56 dB |
|
|
|
12) | Auto electronic shutter | Provided (factory setting OFF) | |||
13) | Automatic gain control (AGC) | Max. 32 dB approx. Fixed gain(factory setting) | |||
14) | Integration mode | Field integration mode | |||
15) | Gamma correction | 0.45 |
|
|
|
|
| 0.45ON (factory setting) or 1.0 | |||
|
| Selected by changing chip parts | |||
16) | Sensitivity | 30 lux , F4, 3200k |
| ||
17) | Minimum illumination | 0.3 lux , F1.4 , AGC and gamma on | |||
18) | Power supply voltage | 9 ± 0.5 VDC |
| ||
19) | Power consumption | Approx. 150mA |
| ||
20) | Ambient conditions | Operating : | |||
|
| Storage : |
3 |