INSTALLATION

1.Using the supplied screws, mount the bracket base on the desired location.

2.Connect the BNC connector of the camera to a monitor or other video device through a 75 ohm type coaxial cable with BNC female connector at cable extension.

3.Connect the 24VAC or 12VDC regulated power source of the camera (power jack) to the power-in jack with 2mm plug. For 12VDC power source, please make sure the power plug is center+ outer- for heater normal operation.

4.If the factory settings are out of focus, or any other adjustment is required, follow the procedures below.

a.Remove the fixing screw in the front, which hold the sun shield cover. Remove the sun shield cover.

b.Twist open and carefully remove the housing cover.

(Please pay attention to prevent damage to the “O”-Ring seal.)

c.Loosen the focal lens and focus locking screws.

d.Adjust the lens to bring the subject into focus.

(Caution: Heater elements could be hot! When camera power is on, be cautious with camera adjustment.)

e.Retighten the screws.

f.Please refer to the Settings section for the details of the other adjustments. Adjust accordingly if necessary.

g.When all the adjustments and settings are completed, overlaying the cover gently. Be careful not to damage to the “O”-Ring and camera components.

h.To reassemble the sun shield, match the hole on the sun shield to the back fixing plate of

4

Image 5
Contents Do not install the camera near electric or magnetic fields PrecautionsPreface FeaturesPackage Contents 12VDC/24VAC SpecificationsDimensions Major Parts Name & Their Functions Installation Page Iris ALC Adjustment SettingsIris Level Adjustment BLC Back Light Compensation ON/OFF FLFlickerless ON/OFFAGC Automatic Gain Control Off/On LL Line-Lock Off/OnDesiccant pack Install the cover and overlaying gentlySimple Instructions for the Desiccant Pack USA L.A. Office USA N.Y. Office Europe Office Head OfficeChina Office Japan Office