EverFocus EZ630 manual Osd Menu Setup, Control Key General Operation Guide, Chapter

Page 18
3 OSD MENU SETUP

Chapter

3 OSD MENU SETUP

3

This chapter introduces how to change RS485 ID and Baud Rate and to configure the camera OSD menu.

STEPS

If you want to connect to the camera with a keyboard or other RS-485 - controller, please refer to Section 3.2 RS485 ID & Baud Rate setting. Otherwise, please go to STEP 2.

Configure the camera, as described below:

3.1 Control Key General Operation Guide

Switch between Lens and Menu operation

Press and hold ( ~ 5 s) the joystick button for changing the operation mode of the joystick. Red LED: Menu mode, Green LED lens control mode.

Bring Up the General OSD Menu

Simply press the mini-joystick to bring up the general OSD menu.

Note: Make sure, that the joystick is in "MENU" mode (red LED under Joystick).

Navigate among the OSD Menu Items

Angle the mini-joystick up (￿) or down (￿) to move the cursor up or down.

Change Modes or Setting Parameters

Angle the mini-joystick left (￿) or right (￿) to adjust the mode or value of settings.

Switch to Sub-menu Screens

When an item with a sub-menu is selected, press in on the mini-joystick to switch to the sub-menu for further settings. This may also be referred to in the instructions below as “pressing the setup button”. Please refer to the diagram below.

SETUP

EVERFOCUS

 

1. LENS

DC

<

DC LENS

2. EXPOSURE

 

 

 

3. WHITE BAL.

AWB

￿BRIGHTNESS +++++++++ 45

4. DAY NIGHT

EXT

5. 3DNR

ON

<

RETURN RET

6. SPECIAL

 

 

 

 

 

7. ADJUST

 

 

Sub-Menu

8. RESET

<

 

 

Main Menu

 

9. EXIT

18

Image 18
Contents Installation / Operation Instructions Low Light Inline IP66 Bullet CameraLow Light IR Inline IP66 Bullet Camera EZ610Operation Instruction P/N 4605XZ0610004ARPrecautions Increase the separation between the equipment and receiver Federal Communication Commission Interference StatementReorient or relocate the receiving antenna Consult the dealer or an experienced radio/TV technician for helpTable of Contents 4.1.3 Lens Adjustment by Keyboard RS - 485 Wiring4.1.2 OSD Menu Setting by Keyboard RS-485 Wiring1.1 Features 1 PRODUCT OVERVIEWChapter 1.2 Accessory Parts List 0.45 1.3 Specifications1/601/50 ~1/100,000 Split glass isolation prevents internal reflections1250 g / 2.275 lbs 1.4 DimensionsWeight Mounting Pattern1.5 Camera Component Description Speedy-mount RingRed Menu mode Green Lens mode 1.6 Related Products EverFocus control keyboard EKB500Any EverFocus DVR with RS-485 interface for PTZ control 2 INSTALLATION 2.1 Wiring and MountingChapter Power and Video connection Video & Power cables RS485 cable optional White RS-485 + Black RS-485Power Socket Power RS-4852.2 Adjust Camera Position 1st axis Use a hexagon key to loosen this screw to rotate the camera2nd axis Use a hexagon key to loosen this screw to rotate the camera 3rd axis Loosen lock ring and set screw to rotate camera Sunshield Loosen this screwPage 3 OSD MENU SETUP 3.1 Control Key General Operation Guide3.2 RS485 ID & Baud Rate Setting 3.3 OSD Menu Setup 3.3.1 OSD Menu Tree3.3.2 LENS 3.3.3 EXPOSURE TOP/BOTTOM 3.3.4 WHITE BALANCE CONTROL 3.3.3.5 D-WDRAuto Tracking White Balance This mode can be used within the color 3.3.5 DAY NIGHT 3.3.7 SPECIAL 3.3.63DNR the light sensor at the front of the camera body. default for EZ6303.3.7.3 FREEZE imagePress “RET” to save all settings in MOTION menu and return to the previous menu. Press “END” to save all the menu settings and exit3.3.8 ADJUST previous menu. Press “END” to save all the menu settings and exit3.3.9 RESET 4.1.1 RS - 485 Wiring RS-485 REMOTE CONTROLRemote control with EKB-500 keyboard 4.1.2 OSD Menu Setting by Keyboard4.2.1 RS-485 Wiring 4.2 Remote Control with EverFocus DVR4.1.3 Lens Adjustment by Keyboard 4.2.2 Camera Operation and Setup by DVREverFocus Electronics Corp