Olympus OM-2, zm2000qdk manual Flashbulb Photography

Page 37

FLASHBULB PHOTOGRAPHY

Plug the synchronizing cable leading from the flash unit into the camera flash socket, and then attach the flash unit to the camera.

Select the proper synchro setting from the table below according to the type of bulb be- ing used, and align the red dot on the X and FP flash selector with the "X" or "FP" in- dication alongside the flash socket.

CAUTION: With the clip-on type "FP" class flash

unit, the synchronizing cable must be used to

connect the unit and the camera.

Select the proper shutter speed from the table

below, and set the shutter speed ring accord- ingly.

Determine the correct F stop for flash exposure by using the calculator dial, exposure chart or guide number formula. Set the aperture ring to this F stop.

The table indicates proper synchronization speeds for most flash equipment.

Recommended;

Not recommended due to bulb quality

36

Image 37
Contents Page To an OM-2 Owner Description of Controls Selector Lever Hot Shoe Socket Self-Timer Depth-of-Field Preview Button Table of Contents On OM System Mounting the Lens Inserting the BatteriesMount the Lens Check the Batteries Battery Check and Mirror LOCK-UPMirror Lock-Up Loading the Film Exposure Counter Exposure CounterWhen Setting ASA Setting the ASA Film Speed DialAperture Ring Aperture Ring and Manual Shutter Speed RingManual Shutter Speed Ring Setting the Selector Lever Viewfinder Focus FocusingOut of focus Aperture-Preferred System Automatic Exposure ControlZoom lenses to 200mm 1/250 second or Shutter Speed-Preferred System Shutter Speed-Preferred Manual Exposure Control Manual Exposure ControlAperture-Preferred Manual Exposure Control If the Exposure Needle Does Not Center on the Index Holding the Camera Horizontally Holding the CameraPutting the Camera into Operation Holding the Camera VerticallyUnloading the Camera Making Multiple Exposures Stopping the Self-timer Setting the SELF-TIMERExposure Compensation Exposure Compensation for Automatic Measurement Dark subject in bright backlighting Exposure Compensation for Manual MeasurementBright subject in dark background Depth of Field Depth of Field Scale Preview Button Infrared Photography Camera Back Replacement Interchangeable Focusing Screens Flash Photography with the T32orT20 Electronic Flash Used Flash Photography with the T32 or T20 Electronic Flash Flash operation Normal automatic TTL Centralized ControlBounce Flash CLOSE-UP Flash With Quick Auto Flashbulb Photography Motor Drive Motor Drive PhotographyAttaching the Motor Drive Release the shutter Winder Winder 2 OperationTaking the pictures Attaching the WinderGeneral Care and StorageParts Why cant I advance the film? Rewind knob rotate when I advance the film?Why wont the shutter release button move When I press it? Why cant I set the ASA film speed I need?When should I check the batteries? Why doesnt the battery chamber cap fit?What batteries should I use? Shoe? How can I remove dust from inside the view- finder?Diagram of light path in conventional SLRs Page Page OM System Zuiko Interchangeable Lens Group Page 16mm F3.5 Table of Interchangeable Lenses181mm 80mm 255mm 80mm Lens Hoods Interchangeable Lens Group UnitsCamera Body Cap Rear Lens Cap Front Lens Caps Adapter Ring 49 72mmGrey Finder Group Finder Group Units For most lenses Finder Group UnitsIs made automatically by the light supply Flash Photo Group Page Flash Photography System Chart Electronic Flash T32 Flash Photo Group UnitsElectronic Flash T20 T10 Ring FlashTTL Centralized Control Flash by T32 T20/ OM-2 Combination Power Control TTL Auto Cords T 0.3m, 0.6m, 2m, 5m Power Bounce GripGrip Cord Zoom Adapter T32ND Filter Set T32 Wide AdapterElectronic Flash AC Adapters Electronic Flash AC AdapterCompartment Case S Lens Pouches 150/100Olympus PS200/PS200 Quick Page Motor Drive Group Page Chart of Motor Drive Group 6V Power Pack Winder 2 with M V Battery Holder18V Control Grip 1 with M V Battery Holder Motor Drive Group UnitsMotor Drive Group Units Macrophotography Group Chart of Macrophotography Group Telescopic Auto Tube Macrophotography Group UnitsAuto Extension Tubes 7, 14 Close-up Lens 49mm f=40cm Close-up Lens 55mm f=40cmFocusing Stage Focusing RailAuto Bellows Objective Lens Mount PM- MTobGrip Cord TTL Auto Cord T 0.3m, 0.6m, 2m, 5mMacrophoto Stand Extension Bar VST-E Macrophoto Stand B AdapterDouble Cable Release Cable Release SR-11 Copy StandTrans-llluminator LSD Epi-llluminators PM-LSDLieberkuhn Reflector PM- LM38 LM20 Centering Mirror PM-ELCSSpare Bulb 6V 5A TP-1 Spare Bulb 6V 5A TB-1Adapter PM-EA Stage Plate 45 metal discPhototechnical Group Page Page Chart of Phototechnical Group For Pen F Phototechnical Group UnitsCable Release SR-11 Photomicrography Group Page Chart of Photomicrography Group Photomicrography Group Units Photomicrography Group Units Chart of Photographic Ranges Hard Case for OM Body Case Group Case Group UnitsSemi-Hard Case for OM Body with F1.8 or F1.4 Lens Pouch Soft Case for OM Body with F1.2Compartment Case M Camera Holder for Case MPartitioned Insert Chart of Case Group Film format 24mm x 36mm Main SpecificationsViewfinder magnification 0.92X at infinity with Dimensions and weights Main SpecificationsWith F1.8 lens 136 x 83 x 81mm With F1.2 lens 136 x 83 x 97mmOlympus Corporation