Olympus zm2000qdk Macrophoto Stand B Adapter, Macrophoto Stand Extension Bar VST-E, Lighting Set

Page 82

MACROPHOTOGRAPHY GROUP UNITS

Macrophoto Stand VST-1

Arugged stand specially design- ed for close-up and high magni- fication photography. Usable with various stage plates. Com- plete with a round frosted plate (black at back) for incident light, and a pair of stage clips.

Macrophoto Stand B Adapter

For use with the Macrophoto Stand, to support the Auto Bel- lows or Focusing Rail on the Stand.

Macrophoto Stand Extension Bar VST-E

Extends the height of the Macro- photo Stand. Length: 7.5cm (2.95").

Trans-llluminator Base X-DE

Indispensable for holding the

Macrophoto Stand VST-1 for magnified photographs. Suppli- ed with a built-in 100V 20W illuminator with a mirror, and a pair of wooden handrests for ease of operation. Can be used with various stage plates and filters.

When used with the Lieberkuhn Reflector, it is convenient to re- place the reflector mirror with the Centering Mirror PM-ELCS.

Double Cable Release

Attached to the Auto Bellows and camera shutter release but- ton, to activate them simultane- ously.

Cable Release SR-11

Copy Stand

A standard type stand, 48 x 44

cm, for general close-up and copy photography. Two additional lights can be attached to the top of the 80cm high stanchion. Fine adjustment for the camera height and a locking device are pro- vided.

Handy Copy Stand

Afour-legged stand for close-up and copy photography. The leg length is adjustable to three po-

sitions.

Lighting Set

Complete with two units, each consisting of a base and light

arm. Max. intensity: 500W.

81

Image 82
Contents Page To an OM-2 Owner Description of Controls Selector Lever Hot Shoe Socket Self-Timer Depth-of-Field Preview Button Table of Contents On OM System Mounting the Lens Inserting the BatteriesMount the Lens Check the Batteries Battery Check and Mirror LOCK-UPMirror Lock-Up Loading the Film Exposure Counter Exposure CounterSetting the ASA Film Speed Dial When Setting ASAAperture Ring Aperture Ring and Manual Shutter Speed RingManual Shutter Speed Ring Setting the Selector Lever Viewfinder Focus FocusingOut of focus Aperture-Preferred System Automatic Exposure ControlZoom lenses to 200mm 1/250 second or Shutter Speed-Preferred System Shutter Speed-Preferred Manual Exposure Control Manual Exposure ControlAperture-Preferred Manual Exposure Control If the Exposure Needle Does Not Center on the Index Putting the Camera into Operation Holding the CameraHolding the Camera Horizontally Holding the Camera VerticallyUnloading the Camera Making Multiple Exposures Setting the SELF-TIMER Stopping the Self-timerExposure Compensation Exposure Compensation for Automatic Measurement Dark subject in bright backlighting Exposure Compensation for Manual MeasurementBright subject in dark background Depth of Field Depth of Field Scale Preview Button Infrared Photography Camera Back Replacement Interchangeable Focusing Screens Flash Photography with the T32orT20 Electronic Flash Used Flash Photography with the T32 or T20 Electronic Flash TTL Centralized Control Flash operation Normal automaticBounce Flash CLOSE-UP Flash With Quick Auto Flashbulb Photography Motor Drive Photography Motor DriveAttaching the Motor Drive Release the shutter Winder 2 Operation WinderAttaching the Winder Taking the picturesCare and Storage GeneralParts Why wont the shutter release button move When I press it? Rewind knob rotate when I advance the film?Why cant I advance the film? Why cant I set the ASA film speed I need?When should I check the batteries? Why doesnt the battery chamber cap fit?What batteries should I use? How can I remove dust from inside the view- finder? Shoe?Diagram of light path in conventional SLRs Page Page OM System Zuiko Interchangeable Lens Group Page Table of Interchangeable Lenses 16mm F3.5181mm 80mm 255mm 80mm Camera Body Cap Rear Lens Cap Front Lens Caps Interchangeable Lens Group UnitsLens Hoods Adapter Ring 49 72mmGrey Finder Group Finder Group Units Finder Group Units For most lensesIs made automatically by the light supply Flash Photo Group Page Flash Photography System Chart Electronic Flash T20 Flash Photo Group UnitsElectronic Flash T32 T10 Ring FlashTTL Centralized Control Flash by T32 T20/ OM-2 Combination Power Control Grip Cord Power Bounce GripTTL Auto Cords T 0.3m, 0.6m, 2m, 5m Zoom Adapter T32Electronic Flash AC Adapters Wide AdapterND Filter Set T32 Electronic Flash AC AdapterCompartment Case S Lens Pouches 150/100Olympus PS200/PS200 Quick Page Motor Drive Group Page Chart of Motor Drive Group 18V Control Grip 1 with M V Battery Holder Winder 2 with M V Battery Holder6V Power Pack Motor Drive Group UnitsMotor Drive Group Units Macrophotography Group Chart of Macrophotography Group Auto Extension Tubes 7, 14 Macrophotography Group Units Telescopic Auto Tube Close-up Lens 49mm f=40cm Close-up Lens 55mm f=40cmAuto Bellows Focusing RailFocusing Stage Objective Lens Mount PM- MTobTTL Auto Cord T 0.3m, 0.6m, 2m, 5m Grip CordDouble Cable Release Macrophoto Stand B AdapterMacrophoto Stand Extension Bar VST-E Cable Release SR-11 Copy StandLieberkuhn Reflector PM- LM38 LM20 Epi-llluminators PM-LSDTrans-llluminator LSD Centering Mirror PM-ELCSAdapter PM-EA Spare Bulb 6V 5A TB-1Spare Bulb 6V 5A TP-1 Stage Plate 45 metal discPhototechnical Group Page Page Chart of Phototechnical Group For Pen F Phototechnical Group UnitsCable Release SR-11 Photomicrography Group Page Chart of Photomicrography Group Photomicrography Group Units Photomicrography Group Units Chart of Photographic Ranges Semi-Hard Case for OM Body with F1.8 or F1.4 Lens Pouch Case Group Case Group UnitsHard Case for OM Body Soft Case for OM Body with F1.2Compartment Case M Camera Holder for Case MPartitioned Insert Chart of Case Group Film format 24mm x 36mm Main SpecificationsViewfinder magnification 0.92X at infinity with With F1.8 lens 136 x 83 x 81mm Main SpecificationsDimensions and weights With F1.2 lens 136 x 83 x 97mmOlympus Corporation