LG Electronics LVC-SX703PC/OC/MC RS-485 Protocol, Data Communication Format, Commands

Page 38

LVC-SX703PC_AA4HEL_ENG_MFL-129 11/7/06 12:06 PM Page 38

RS-485 Protocol

Data Communication Format

Data Length: 1 Byte (8 Bit)

Start/Stop Bit: 1 BIT

Parity Bit: None

Baud rate: 9,600 bps

Format

BYTE 1 BYTE 2 BYTE 3 BYTE 4 BYTE 5 BYTE 6

0xC5 CODE1 CODE2 CODE3 CAM_ID *C.S.

*C.S. = Check Sum

The data of total 6 bytes is transmitted from the external RS-485 device to the camera.

BYTE 6 : The value of Check Sum from ‘BYTE 1 ’ to ‘BYTE 5 ’.

ex) In case of transmission, 0xC5, 0x5F, 0x02, 0x00, 0x0A”

C.S. = 0xC5 +0x5F +0x02 +0x00 +0x0A = 0x0130 therefore, C.S. = 0x30

Commands

Function

Command

 

(external device camera)

OSD Menu ON/OFF

0xC5, 0x5F, 0x25, 0x00, ID, C.S.

LEFT Button

0xC5, 0x5F, 0x38, 0x00, ID, C.S.

Right Button

0xC5, 0x5F, 0x39, 0x00, ID, C.S.

Up Button

0xC5, 0x5F, 0x02, 0x00, ID, C.S.

Down Button

0xC5, 0x5F, 0x04, 0x00, ID, C.S.

Menu Button

0xC5, 0x5F, 0x24, 0x00, ID, C.S.

 

 

You must send “Stop” command to camera after sending each command described above.

The “Stop” command is “0xC5, 0x5F, 0x0C, 0x00, ID, C.S.”.

38

Image 38
Contents Color Video Camera LVC-SX703PB/OB/MBRisk of Electric Shock Do not Open Important Safety Instructions Manufacturer Contents and Features Features Chart Power SourceIs operated with Line lock mode Remove dust or dirt on the surface of the lens with a blowerLens mount cap Installing a lens sold separatelyPart Names and Functions Bracket can be fixed at the top or bottom of the camera.External Device Connectors RS-485 Connector Power input terminalPower indicator Buttons for menu ALC Lens Setting SwitchLens iris output connector Lens Tons on the side panel.Connections Connecting the monitorInsert the plug of this power cord into a wall outlet Basic connectionMounting the Lens Mount type lensVideo type auto-iris lens Concerning Auto-Iris LensesDC type auto-iris lens ELC type auto-iris lensRS-485 Connection Alarm ConnectionExternal Device Connections Multi-Input ConnectionFlange-back Adjustment Installation of Camera Menu Operation To Open and Exit the Menu screen Exit the menu screenCamera Identification Setting Language and Camera Identification SettingsLanguage Setting You can set the brightness level levels Exposure SettingsBrightness Setting Automatic Gain Control AGC setting ExposureUse for removing the flicker of picture Shutter Speed Setting ShutterFlickerless Setting Flikerless Use BLC/WDR option to set the options for BLC or WDR camera BLC/WDR SettingYou can set the exposure options using the Exposure menu Use or button to select BLC/WDR optionBLC/WDR User Level Area Bottom White Balance Settings Setting the WB White Balance Mode WB Mode Push Auto Day/Night Setting Motion Detector Setting Motion DET Condition Detection AreaSensitivity Privacy Masking Setting Privacy MaskSpecial Menu Settings SpecialSetting the digital effect Effect Effect OFFRepeat to set the remain characters Setting the digital zoom D-ZOOMNaming the camera USER-TITLE Setting the title display Setting the HOT KEYSynchronization Setting Sync Setting the Pix Mapping RS-485 Protocol CommandsStop command is 0xC5, 0x5F, 0x0C, 0x00, ID, C.S Data Communication FormatSpecifications Storage Temperature Electric Shutter 50 1/100,000 Auto Mode White BalancePower Consumption Weight