Functionality
Power supply
The D1 unit can be connected to 100-120 VAC or 200-240 VAC, 50-60 Hz. The unit automatically senses and adapts to the supplied voltage and frequency.The power supply fuses must not be smaller than specified in the sectionTechnical data.
Most gas generators with an output of 800W constant load, or more, can power the D1 unit. Thanks to the two stage SMPS (Switch Mode Power Supply) technology, no ProGas unit is needed.

Profoto Air USB – Profoto Studio Air

10WARNING:

Never use ordinary household extension cords to elongate the power cable.They may overheat.Always unwind cord reel extension winders fully before useContact. your Profoto dealer for proper equipment.

Due to the two stage SMPS technology, the D1 could make a hearable sound during the recharge cycle.This is fully normal and could be seen as the sign ofwerpo being charged into the unit.

Energy control

The current energy level of the flash light is shown in the Display [1] in f-stop scaleThe. maximal energy (100%) is shown as 10.

The Setting Knob [7] is used to adjust the energ y level, in 1/10 f-stop or 1 f-stop increments.

Modeling light

The Model Button [10a] is used to select one of three modeling light alternatives:

PROP: The modeling light intensity is automatically adjusted to correspond to the energy level of the flash light.

FREE: The modeling light intensity is manually set,free from any connection to the energy level of the flash light.

OFF: No modeling light.

The Model Set Button [11],in combination with the Setting Knob [7],is used to change the level of the free modeling light.

Sync signaling

The D1 unit can be synchronized in different ways; via cable,via infrared (IR) light or via the ProfotoAir radio system.

The 5 meter sync cable can without restrictions be elongated with a sync extension

cable. The Profoto sync interconnection cord or so called “hard wiring” may be used.

www.profoto.com

Image 10
Contents D1 1000 Air D1 500 Air D1 250 Air AirStudio Profoto Thank you for choosing Profoto Safety instructions Safety PrecautionsTable of Contents System description Profoto AirProfoto Air USB Profoto Air RemoteProfoto Air Sync Profoto Studio AirSlave Setting NomenclatureSync Connector Locking Knob Energy control Sync signalingModeling light Ready indicator/Test function Ready signalingFlash before ready Reflector Remote controlColor temperature UmbrellaOperating instructions Modeling light setting Ready signaling settingSync via IR Radio settings D1with Profoto AirSync via cable Sync via radio D1without Profoto AirTurn off unit Changing flash tube and/or modeling lamp MaintenanceClasp Flash tube Modeling lamp Changing built-in fuse Adaptive thermal control 250 Air 1000 Air500 Air 500Synchronization modes This page is intentionally left blank This page is intentionally left blank Change without notice