Fairchild CAM/CCD-4KCL.TDI, CAM/CCD-2KCL.TDI user manual Tsb, Ssm, Scm, Stp

Page 18

TSB

This command reads the internal camera temperature.

The camera returns

Temp 39.42°C (example)

SSM

This command allows you to set the Sync mode. When selecting the option you need, first type SSM and press enter and then enter the appropriate single digit number, and then press enter.

Value Function

1Free Run

2Frame Mode

3Line Sync

4External Line Sync, Frame Mode

SCM

This command allows you to select a correction mode. When selecting the option you need, enter the appropriate single digit number and then hit enter.

 

Value

Function

The camera returns

1

M1

(1st memory)

 

2

M2

(2nd memory)

 

3

Offset Correction

 

4

Gain Correction

 

5

No Correction

 

6

Full Correction

STP

This command allows you to select a test pattern. When selecting the option you need, enter the appropriate single digit number, and then hit enter.

Value

Function

No output from camera1

Horizontal Ramp

2

Vertical Ramp

3

Vertical Stripes and Ramp

4

Open

5

4096

6

0

Other

Video

Fairchild Imaging • CAM/CCD 2KCL.TDI & CAM/CCD-4KCL.TDI Line Scan Camera User’s Manual • Rev C• 18 of 30

Image 18
Contents Osprey Camera Series EMC Conformance EMCCAM/CCD-2KCL.TDI & CAM/CCD-4KCL.TDI Revision B December 14 Fairchild Imaging, IncTable of Contents Troubleshooting Product SupportIntroduction to High Performance TDI Line Scan CameraCamera Highlights Programmability UsabilityFull Spectrum of Applications Camera Specification CAM/CCD-2KCL.TDI & CAM/CCD-4KCL.TDI Performance SpecificationBlock Diagram CCD525 2048 x 96 stages Image SensorBlock Diagram CCD545 4096 x 96 stages 2K/4K TDI Camera Timing Diagram 2K TDI CameraLinkTM 4K TDI CameraLinkTMThermal Considerations Installation Overview Camera Hardware InterfaceGood TDI Synchronization Connectors, Pinouts, and Cables MDR-26 CameraLinkTM Connector 3M p/n 334 34 series Power Supply Hirose HR25-7TR-6P ReceptacleCamera Control Camera Control Signals using Camera Link InterfaceCommands Quick Start with the CameraLinkTM InterfaceINQ RSHRSS VERSCM TSBSSM STPSAP CBRLED RAPCamera Command Summary SONSOA Framing Mode How to Operate in Framing ModeMechanical and Optical Considerations Camera Dimensions and Mounting Facilities LensingPage Lenses IlluminationLight Sources Electrostatic Discharge Cleaning the Sensor WindowHandling Instructions Preventing ESD DamageTroubleshooting General SolutionsCheck Simple Things First Noisy Output EXSyncOffset Variation or Drifts Horizontal Lines or Patterns in OutputImages look noisy Bits that do not change valueContact Customer Support Mclk ExsyncBIN Prin