Fairchild CAM/CCD-2KCL.TDI, CAM/CCD-4KCL.TDI user manual Cbr, Led, Sap, Rap

Page 19

CBR

This command allows you to change the Baud Rate. You will not see anything on your monitor.

Here is a table of stored rates in the cameraValue Function

1

9600

2

19200

3

38400 (Default)

4

57600

5

115200

If you cant resist changing the baud rate, select the appropriate single digit number and hit enter.

LED

This command allows you to change the color. When selecting the option you need to, enter the appropriate single digit number and hit enter. Your screen will be blank during this command. You can input one of the following:

Value

Function

0

Amber

1

Green

2

Red

3

Off

SAP

Store in Flash both correction memories, all registers and DAC values.

 

Value

Function

Store all parameters

0

Default factory calibrate

 

1

User

 

2

User

The power on values will be the last saved from SAP (X).

RAP

Load from flash to camera. Recall all parameters

 

Value

Function

 

0

Default factory calibration

 

1

User

 

2

User

SBS

 

 

 

Value

Function

Set bit shift

0

10 bit

 

1

9 bit

 

2

8 bit

Fairchild Imaging • CAM/CCD 2KCL.TDI & CAM/CCD-4KCL.TDI Line Scan Camera User’s Manual • Rev C• 19 of 30

Image 19
Contents Osprey Camera Series EMC EMC ConformanceRevision B December 14 Fairchild Imaging, Inc CAM/CCD-2KCL.TDI & CAM/CCD-4KCL.TDITable of Contents Product Support TroubleshootingHigh Performance TDI Line Scan Camera Introduction toCamera Highlights Usability ProgrammabilityFull Spectrum of Applications Performance Specification Camera Specification CAM/CCD-2KCL.TDI & CAM/CCD-4KCL.TDIImage Sensor Block Diagram CCD525 2048 x 96 stagesBlock Diagram CCD545 4096 x 96 stages 4K TDI CameraLinkTM 2K/4K TDI Camera Timing Diagram 2K TDI CameraLinkTMThermal Considerations Camera Hardware Interface Installation OverviewGood TDI Synchronization MDR-26 CameraLinkTM Connector 3M p/n 334 34 series Connectors, Pinouts, and CablesHirose HR25-7TR-6P Receptacle Power SupplyQuick Start with the CameraLinkTM Interface Camera Control Signals using Camera Link InterfaceCommands Camera ControlVER RSHRSS INQSTP TSBSSM SCMRAP CBRLED SAPSON Camera Command SummarySOA How to Operate in Framing Mode Framing ModeMechanical and Optical Considerations Lensing Camera Dimensions and Mounting FacilitiesPage Illumination LensesLight Sources Preventing ESD Damage Cleaning the Sensor WindowHandling Instructions Electrostatic DischargeGeneral Solutions TroubleshootingCheck Simple Things First Horizontal Lines or Patterns in Output EXSyncOffset Variation or Drifts Noisy OutputBits that do not change value Images look noisyContact Customer Support Prin ExsyncBIN Mclk