Indoor Flush Mount Type Installation
1.Attaching Flexible Adaptor
To feed the cables through a pipe to a flush housing, attach the flexible adaptor enclosed with the product. To attach the flexible adaptor, the install base must be disassembled as shown in the picture. To disassemble the install base, unscrew the 3 screws on the bottom.
Silicon Cap
Adaptor Nut
Flexible Adaptor
Install
| 2. Attaching Template | ||||||
| Attach the enclosed template to a desired location on the ceiling. Drill 3 holes of 50 mm | ||||||
| |||||||
STH | diameter in | ||||||
200 mm hole in the center of the template. | |||||||
- |
|
|
|
|
|
|
|
370PE | 3. Wiring and Arranging | ||||||
| |||||||
| Attach the enclosed turnbuckle and eyebolts inside the ceiling, and then drop the camera | ||||||
| cables down from the ceiling through the hole. | ||||||
|
|
|
|
|
| Turnbuckle | |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Eyebolt
Template | Φ200 mm | Ceiling | Template |
Notes
• Do not connect the camera to a power outlet until the installation is complete. Supplying power in the middle of the installation may cause fire or damage the product.
Indoor Flush Mount Type Installation
4. Preparing Housing | Knob |
Open the hinged door at the bottom of the housing. |
|
While pressing the spring lock (1), hold up the lid to |
|
open (2). |
|
5.Inserting the flush housing
Arrange the cables and eyebolts as shown in the picture, and then insert the housing into the ceiling hole.
Hanger Bolt
Eyebolt
Eyebolt
Fixing Nut | Elbo bracket |
6.Securing Screws or Internal Supports
Two fixture methods are available for the flush mount: screw through or inner support. Depending on the situation, select one of the two methods.
The inner support method unfolds the supports inside the mount when 3 screws on the mount surface are fastened.
ScrewThroughType | Inner SupportType |